Installation manual 1 Safety Precautions This appliance can be used in public areas. Remove all objects from pockets such as lighters and matches. WARNING. This appliance is intended only for drying textiles washed in water. DO NOT MODIFY THIS APPLIANCE. Servicing shall be carried out only by authorized personnel.
Installation manual 2 Technical data fig.W01225 Control panel Electrical connection Electrical connection for external fan Exhaust air connection 1200 1970 1910 1100 Exhaust air connection ⌀125 mm, maximum permitted pressure drop 70 Pa, which corresponds to a straight pipe with a length of approx.
Installation manual 4 Installation Place the drying cabinet on its final position. The straps around the adjustable feet can be used to raise the drying cabinet. Level the drying cabinet with the adjustable feet. Make sure that the top edges of the doors are level with each other. 4.1 Placement The drying cabinet should be positioned so that there is plenty of room for working, both for the user and service personnel.
Installation manual 4.3 Narrow spaces To facilitate transport, there are straps around the adjustable feet. The upper part of the drying cabinet can be disassembled by loosening the eight screws. Removing the upper part reduces the height by 180 mm. •...
Installation manual 5 Evacuation system 5.1 Fresh air The drying cabinet must be connected directly to the ventilation duct (not via any intermediate pipes or hoses). The drying cabinet has an exhaust air flow of up to 250 cubic meters per hour. This air is initially taken from the room where the drying cabinet is situated.
Page 11
Installation manual If multiple drying cabinets or dryers are connected to the same air duct, a non-return valve must be installed on each appliance to prevent cold air from entering or the air pressure of one appliance affecting the other. fig.W01231 Number of cabinets...
Installation manual 6 Electrical connection The electrical installation may only be performed by qualified personnel. The drying cabinet must be connected to an all-pole circuit breaker. Heating options Mains voltage Heat output Total output Recommended fuse Electrically heated 400V 3N ~ 10 / 13 auto fuse...
Installation manual 7 Function check May only be performed by qualified personnel. A function check must be performed when the installation is finished and before the appliance can be used. Whenever a repair has been made, a function check must be performed before the appliance can be used again. •...
Installation manual 8 Disposal information 8.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.