Sanyo SAP-C302AH-S Technical & Service Manual page 7

Table of Contents

Advertisement

2-2-2. Outdoor Unit
Outdoor Unit
SAP – C302AH
Circuit Board Ass´y
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Type
Overload relay
Safety
devices
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor ... Q´ty
Crank case heater
Type
Q´ty ... Dia.
Fan motor model ... Q´ty
No. of poles .... Cool / Heat rpm (High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Type
Safety
devices
Operating temp.
Run capacitor
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
µF
VAC
mm
W
Open
°C
Close
µF
VAC
mm
2
m
4
POW – C301AH-A
Rotary (Hermetic)
C – R240H5S 80669545
2,400
4GSD – T or SAY–56T ... 1,350
C – R : 0.944
C – S : 1.732
Internal protector
Automatic opening
Automatic reclosing
35.0 ... 2
400 ... 2
240V 25W
Propeller
1 ... ø 460
KFC6S – 91D5P–S ... 1
6 ... 780 / 760
90
WHT – BRN : 129.0
WHT – YEL : 57.4
YEL – PNK : 22.1
Thermal protector
130 ± 8
Automatic reclosing
6.0
440
Aluminum plate fin / Copper tube
2
1.8
0.529
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.