IW-RS216-07 HYBRID BACKPLANE
USER MANUAL
P/N : 2RAKVI008900
Model
I W-RS216-07 3.5" 4BAY HYBRID BACKPLANE-V
: : : :
MODULE
Version : V1.0
Model : IW-RS216-07 Hybrid Backplane User Manual
PAGE 1 OF 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W-RS216-07 and is the answer not in the manual?

Questions and answers

Summary of Contents for InWin W-RS216-07

  • Page 1 IW-RS216-07 HYBRID BACKPLANE USER MANUAL P/N : 2RAKVI008900 Model I W-RS216-07 3.5” 4BAY HYBRID BACKPLANE-V : : : : MODULE Version : V1.0 Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 1 OF 15...
  • Page 2 Revision History Version Changes Date V1.0 Official Release 2021/05/25 Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 2 OF 15...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Overview ....................... 4 Physical Outlook ....................... 4 Mechanical ........................5 Connector Locations and LED Indicators ........... 6 Connector/ LED Indicators....................6 Connector Pin Definitions....................7 Hardware Specification ................9 LED Behavior ....................10 Disk Bay LED ......................... 10 System Alarm LED ......................
  • Page 4: Overview

    Overview InWin backplanes (without Expander) are high performance and cost effective solution for supporting Intel Purley platform by adding NVMe support. The passive backplanes support state-of-the-art SAS3 12Gbps HDD/SSD and also backward compatible with SAS 6Gbps, SATA 6Gps and SATA 3Gps HDD/SSD. The backplane supports NVMe SSD through OcuLink x4 connectors.
  • Page 5: Mechanical

    Mechanical Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 5 OF 15...
  • Page 6: Connector Locations And Led Indicators

    Connector Locations and LED Indicators Description Description Host facing interface : NVME1~NVME4 FAN Connector : FAN1~FAN4 Host facing interface (SAS3) : CN1 M/S BP Selection Switch : S1 M/S Communication Connector : JB1 Firmware Programming Header : J D1 M058 Micro-controller : IC1 Main Power Connector P W1 :...
  • Page 7: Connector Pin Definitions

    Connector Pin Definitions. NVME1~NVME4 Power 5-Pin Connector PIN # Definition +12V 2 & 3 Ground Firmware Programming Connector PIN # Definition PIN No# Definition ICE_CLK ICE_DATA #Key ICE_RST Ground Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 7 OF 15...
  • Page 8 FAN1~FAN4 FAN 4-Pin Connector PIN # Definition Ground +12V Tachometer PWM Output M/B FSC 3-Pin Connector PIN # Definition MB_PWM BP_TACH Groubd S1 M/S Selection Function Description S1 M/S Selection Function Description 00 : BP_MASTER 10 : BP_slave2 01 : BP_slave1 11 : BP_slave3 Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 8 OF 15...
  • Page 9: Hardware Specification

    Hardware Specification HOST Facing Interface M iniSAS HD/OCulink : DEVICE Facing Interface S ATA/SAS/NVMe : Indicator : Indicator : Power LED PD1~PD4: Steady Blue –(When HDD is resent) Dual color(Green/Red) LED D1~D4 for Hard Disk Drive Status (Activity/Failure/Locate) Activity LED: Blinking Green (When HDD is Access) Locate LED : Blinking Red (When HDD Fail or Locate) Fail LED : Steady Red (When HDD Fail or Locate) Environment Control :...
  • Page 10: Led Behavior

    LED Behavior Disk Bay LED Blue LED: Disk Insertion Indicator – Turned on whenever disk drive is properly installed. Green LED: Activity indicator – Stay off when idle and blinking (~8 Hz) whenever disk drive is being accessed. RED LED: Fail and Locate indicator –...
  • Page 11: System Alarm Led

    For NVMe application, The LEDs behave according to the VPP over I2C signals from NVMe host controllers through sideband bus of Oculink or SlimSAS cables. Whenever the NVMe host controller support VPP over I2C, the RED LEDs behave Locate, Fail and Rebuild signals following VPP signals on the I2C bus.
  • Page 12: Smart Fan Control

    Fail LED stays steady on when both events triggered at the same time. Smart Fan Control InWin’s Backplane is implemented Smart Fan Control feature by automatically detecting the existences of the Fan Modules and intelligently control the Fan RPM per the system temperature being detected by two thermal sensors (RTB1/RTB2) on the backplane.
  • Page 13 spreading from 25 to 45 in 3.75 degree C step. ° C 4. In normal operation, when the system temperature changes to next level, the fan module would change speed accordingly. And, the Fan failure alarm would be triggered when the RPM of the Fan module is dropped lower than 75% of its expected speed.
  • Page 14: Firmware Upgrade

    Firmware Upgrade The passive backplanes are planted Nuvoton M058 series MCUs for hosting disk LED indication, Fan speed control and system fail alarm. These MCUs are preprogrammed in manufacturing. In most cases, the MCUs are not required to reprogram unless there is issue needed to fix.
  • Page 15 3. Make sure device is connected and select the binary file being programmed and then click on Start button to program firmware. 4. Please refer to http://www.nuvoton.com/resource- files/NuLink_Adapter_User_Manual_EN_V1.01.pdf for more details. Model : IW-RS216-07 Hybrid Backplane User Manual PAGE 15 OF 15...