INSTALLATION MANUAL
DuraVent 46DVA-_FF Co-axial DV Flex
DuraVent 46DVA-36FF 36", 46DVA-60FF 60", 46DVA-120FF 120"
Use with listed Valor models (see appliance manual for listing of these components
 WARNING
This kit must be installed or serviced
by a qualifi ed installer, service agency
or gas supplier. These instructions
are to be used in conjunction with
the fi replace main installation
instructions for the qualifying Valor
heater models.
These fl ex pipes are intended to be used for off sets and
bends between 2 pieces of rigid pipe/elbow or between
the appliance (equipped with a DuraVent collar) and
another section of pipe/elbow—you will require rigid
pipe sections in all cases to complete the vent system.
DO NOT CONNECT THIS FLEX DIRECTLY TO A VENT
TERMINAL!
Use of these fl ex kits does not change allowable vent
confi gurations—refer to appliance manual for allowable
vent confi gurations. A 90 degrees bend using fl ex is
equivalent to a 90 degrees bend using rigid pipe.
The appliance end of this fl ex will only fi t DuraVent style
pipe collars. The termination end of this fl ex will accept
other brands of pipe/elbow listed in appliance manual.
Tape all external joints including where fl ex meets
collars, using high quality, high-temperature, 2" wide
self-adhesive aluminum foil tape (Nashua 322-2 brand
or similar). Wrap the tape completely around all joints
and press fi rmly to seal.
DO NOT cut fl ex.
DO NOT run fl ex through walls, fl oor, ceiling or roof.
DO NOT run fl ex completely horizontal—maintain a
minimum 5% rise between end collars of fl ex section,
i.e. minimum 2" rise over 36" length and a minimum 6"
rise over a 120" length.
DO NOT use more than one fl ex section per vent
system.
DO NOT overstretch fl ex—stretch it only to length
required.
4006655-03
© Copyright Miles Industries Ltd., 2021
CO-AXIAL FLEX
This kit must be installed or serviced
by a qualifi ed installer, service agency
or gas supplier. These instructions
are to be used in conjunction with the
fi replace main installation instructions
for the qualifying Valor heater models.
DO NOT USE fl ex in exposed applications—exposed in
service rooms and service closets acceptable. Protect
fl ex from mechanical damage.
Flex must be supported or strapped every 2'-0" to
maintain clearances to combustibles.
46DVA-36FF
46DVA-60FF
46DVA-120FF
1

Advertisement

Table of Contents
loading

Summary of Contents for Valor DuraVent 46DVA FF Co-axial DV Flex Series

  • Page 1 CO-AXIAL FLEX DuraVent 46DVA-_FF Co-axial DV Flex DuraVent 46DVA-36FF 36", 46DVA-60FF 60", 46DVA-120FF 120" Use with listed Valor models (see appliance manual for listing of these components This kit must be installed or serviced  WARNING by a qualifi ed installer, service agency This kit must be installed or serviced or gas supplier.
  • Page 2: Clearances To Combustible Material

    Flex Pipe Characteristics 6-5/8 x 4” Screws– Detachable collar minimum at end towards termination Spring spacer 4” inner flex 7” flex (nominal) (approx. 7-1/2” o.d.) 6-5/8 x 4” fixed collars at end towards appliance Compressed Inner Flex Stretched Inner/Outer Flex Stretched Clearances to Combustible Material 3”...
  • Page 3: Typical Applications

    Typical Applications Wall termination with “slip” Short rigid pipe connection section thru wall Rigid elbow (used to keep pipe closer to wall and avoid/eliminate possible gooseneck in flex) Wall thimble (required for combustible construction) Flex pipe to Rigid pipe provide offset section This end will ONLY fit to DuraVent style collars...
  • Page 4: Installation

    1. Determine the approximate desired length and DuraVent collar (supplied separately) shape of the fl ex before installing. Valor part no. 4000925 2. Pre-stretch the fl ex to the approximate length and shape before installing the fl ex to the appliance or pipe.
  • Page 5: Guide D'installation

    FLEX COAXIAL DuraVent 46DVA-_FF Conduit coaxial fl ex DV DuraVent 46DVA-36FF 36", 46DVA-60FF 60", 46DVA-120FF 120" Utilisez avec les foyers Valor admissibles (voir liste des accessoires d'évacuatioin certifi és dans le guide d'installation du foyer) Cet article doit être installé et  AVERTISSEMENT...
  • Page 6 Dégagements des matériaux combustibles dégagement min. de 3" dégagement min. de 1" dégagement min. de 1" Rayon de courbe min. de 7” Courbe 90° maximum (pas de courbe en "col-de-cygne") Sections verticales > 45° = minimum 1” de dégagement 46DVA-36FF 46DVA-60FF 46DVA-120FF exigé...
  • Page 7: Applications Typiques

    Applications typiques Sortie d’évacuation à raccordement Section de conduit “coulissant” rigide à travers le mur Coude rigide (utilisez pour garder le conduit près du mur et éviter/éliminer la possibilité du col-de-cygne dans le flex) Fourreau (exigé pour construction combustible) Conduit flex pour un décalage Section de conduit rigide...
  • Page 8 fl ex intérieur et extérieur séparément. Buse DuraVent (vendue séparément) 1. Déterminez la longueur approximative désirée et Pièce Valor n 4000925 formez le conduit fl ex avant l’installation. 2. Étirez le conduit fl ex à la longueur approximative et formez-le avant de le raccorder au foyer ou à...

This manual is also suitable for:

Duravent 46dva-36ffDuravent 46dva-60ffDuravent 46dva-120ff

Table of Contents