Advertisement

Quick Links

V
M
ESTIL
ANUFACTURING
2999 N. Wayne St., Angola, IN 46703
Ph: 260-665-7586 · Fax: 260-665-1339
E-mail: sales@vestil.com • Website: www.vestil.com
M
ODELS
Installation Instructions ........................................... 2
Operation Instructions ........................................ 3
Routine Maintenance & Safety Checks .................. 4
Exploded Structural Parts Drawing & BOM ............ 5-8
Motor and Transformer Connections ............................ 9
W
ARNINGS AND
Ensure that all employees understand and follow the following.
Read and understand the owner's manual before using or servicing
o
the tilting table.
The load must be removed, and the platform either positively and
o
adequately supported or fully tilted, before any work is performed
on the tilter.
Ensure that all safety and warning labels stay in place and are
o
legible.
Do not use the tilting table if any damage or unusual noise is
o
observed.
Always watch the platform and the container carefully when the
o
tilter is in operation.
Do not perform any modifications to the tilting table without the
o
manufacturer's approval. Failure to receive authorization for
changes to the equipment could void the warranty.
Maintenance and repairs are to be done only by personnel qualified
o
to perform the required work.
Do not use brake fluid or jack oils in the hydraulic system. If oil is
o
needed, use an anti-wear hydraulic oil with a viscosity grade of
150 SUS at 100°F, (ISO 32 cSt @ 40°C), or Dexron transmission fluid.
Contact the manufacturer for any needed MSDS information.
o
EM1-200
EHTT
V
M
. C
ESTIL
FG
O
C
.
ORP
EM1-200 & -500, EHTT, EHTT-L
Serial number ____________
S
I
AFETY
NSTRUCTIONS
EM1-500
EHTT-L
03/05
O
WNER
M
Electrical & Hydraulic Diagrams & BOM ............. 10-12
Power Unit's Operation ...................................... 13
Troubleshooting .............................................. 14
Safety Label Identification ........................................ 15-16
Warranty ....................................................... 17
03-126-120.doc
'
S
ANUAL
WHEN ORDERING
:
REPLACEMENT PARTS
We take pride in using quality
parts on the equipment we
manufacture. We are not
responsible for equipment
problems resulting from the use
of unapproved replacement
parts.
To order replacement or
spare parts for this equipment,
contact the factory.
In any communication with
the factory please be prepared
to provide the machine's serial
number, which is indicated on
the machine dataplate.
R
ECEIVING INSTRUCTIONS
Every unit is thoroughly
tested and inspected prior to
shipment. However, it is
possible that the unit could
incur damage during transit.
Inspect the unit closely when
it arrives. If you see evidence
of damage or rough handling to
either the packaging or to the
product when it is being
unloaded, immediately make a
note of it on the Bill Of Lading!
It is important that you
remove the product's packaging
upon its arrival to ensure that
there is no concealed damage
or to enable a timely claim with
the carrier for freight damage.
Also verify that the product
and its specifications are as
ordered.
1

Advertisement

Table of Contents
loading

Summary of Contents for Vestil EM1-200

  • Page 1 ANUFACTURING 2999 N. Wayne St., Angola, IN 46703 ANUAL Ph: 260-665-7586 · Fax: 260-665-1339 E-mail: sales@vestil.com • Website: www.vestil.com EM1-200 & -500, EHTT, EHTT-L ODELS Serial number ____________ Installation Instructions ………………......2 Electrical & Hydraulic Diagrams & BOM ………..10-12 Operation Instructions ……………………….……..
  • Page 2 03/05 03-126-120.doc – EM1-200 & -500, EHTT, EHTT-L NSTALLATION NSTRUCTIONS Review this entire page before installing the tilting table. Consult the factory in the event there are any questions or problems at the time of installation, or for information regarding optional features not covered by the owner’s manual.
  • Page 3 Note: The tilter is “raising” when the platform to which the cylinder is attached is moving to the level position. Therefore, on standard EM1-200 and EM1-500 units, the cylinder(s) will extend when the “UP” control is pressed. On standard EHTT and EHTT-L units, the cylinder(s) will retract when the “UP” control is pressed.
  • Page 4 03/05 03-126-120.doc & S – EM1-200 & -500, EHTT, EHTT-L OUTINE AINTENANCE AFETY HECKS Warning: Care should be taken to identify all potential hazards and comply with applicable safety procedures before beginning work. Warning: The load must be removed, and the platform either positively and adequately supported or fully tilted, before any work is performed on the tilter.
  • Page 5: Exploded Parts View

    03/05 03-126-120.doc -- EM1-200 XPLODED PARTS VIEW -- EM1-200 ILL OF ATERIALS Item #: Description Part number Qty. Pin assembly, hinge, 1 ”Ø 03-612-001 Pin assembly, cylinder, 1”Ø 03-612-002 2 or 4 Cylinder, 2” x 8” 99-021-919 1 or 2 Snap ring, 1”...
  • Page 6 03/05 03-126-120.doc -- EM1-500 XPLODED PARTS VIEW -- EM1-500 ILL OF ATERIALS Item #: Description Part number Qty. Pin, hinge block, 1 ”Ø x 4 ” long 09-112-009 Pivot block, hinge 09-516-012 Bolt, ¾”-10 UNC x 3” long, Grade 5 Nut, nylock, ¾”-10 UNC Cylinder, 3”...
  • Page 7 03/05 03-126-120.doc -- EHTT XPLODED PARTS VIEW -- EHTT ILL OF ATERIALS Item #: Description Part number Qty. Weldment, base 38-514-009 Weldment, platform 38-513-003 Stop block, hinge 38-037-002 Cylinder, 3” x 10” 99-021-902 1 or 2 Pin, hinge assembly, 1”Ø 03-612-002 Pivot block, hinge 34-516-001...
  • Page 8: Bill Of Materials

    03/05 03-126-120.doc -- EHTT-L XPLODED PARTS VIEW -- EHTT-L ILL OF ATERIALS Item #: Description Part number Qty. Weldment, frame 03-514-012 Weldment, deck 03-513-018 Bushing, machine, 1”ID x 18 gauge Snap ring, 1” external Roller, w/ 1 ” ID sleeve bearing; 2” OD x ”...
  • Page 9: Connection Diagrams

    03/05 03-126-120.doc & T OTOR RANSFORMER ONNECTION IAGRAMS ! If the motor voltage is changed, the wire on the control transformer’s primary wire has to be changed to AUTION match the new motor voltage also. ESTIL...
  • Page 10 03/05 03-126-120.doc -- EM1-200 & -500, EHTT, EHTT-L LECTRICAL IAGRAMS o Warning: Care should be taken to identify all potential hazards and comply with applicable safety procedures before beginning work. Ensure that all system pressure and power have been removed before attempting to work on the electrical or hydraulic systems.
  • Page 11 Caution: Do not use brake fluid or jack oils in the hydraulic system. If oil is needed, use an anti-wear hydraulic oil with a viscosity of 150 SUS at 100°F (ISO 32 @ 40°C), or non-synthetic transmission fluid. Model EM1-200 Models EM1-500, EHTT, EHTT-L...
  • Page 12 01-129-001 Transformer, control; w/ 24 VAC secondary AGC 2 Fuse, for control circuit 01-029-006 Control enclosure, 6”W x 6”L x 4”D (EM1-200) 01-029-007 Control enclosure, 6”W x 8”L x 4”D (EM1-500, EHTT, EHTT-L) 01-522-015 Pushbutton control on 8’ cord 1 or 2...
  • Page 13: The Power Unit

    ♦ The pressure-compensated flow control spool (EM1-200 only). This regulates the fluid flow back to the reservoir when the valve opens. It allows the platform to always lower at the same rate regardless of whether there is a load on the platform or not.
  • Page 14 03/05 03-126-120.doc -- EM1-200 & -500, EHTT, EHTT-L ROUBLESHOOTING UIDE o Warning: The load must be removed, and the platform either positively and adequately supported or fully tilted, before any work is performed on the tilter. Consult the factory for problems at time of installation, or for any problems not addressed below.
  • Page 15 03/05 03-126-120.doc -- EM1-200 & -500, EHTT, EHTT-L AFETY ABEL DENTIFICATION * Product safety signs or labels should be periodically inspected and cleaned by the product users as necessary to maintain good legibility for safe viewing distance -- ANSI 535.4 (10.21). Contact the manufacturer for replacement labels.
  • Page 16 03/05 03-126-120.doc ESTIL...
  • Page 17: One-Year Limited Warranty

    03/05 03-126-120.doc ’ W OWERED PRODUCTS ARRANTY ONE YEAR LIMITED WARRANTY The manufacturer warrants for the original purchaser against defects in materials and workmanship under normal use one year after date of shipment (not to exceed 15 months after date of manufacture). Any part that is determined by the manufacturer to be defective in material or workmanship and returned to the factory, shipping costs prepaid, will be, as the exclusive remedy, repaired or replaced at our option.
  • Page 18 03/05 03-126-120.doc OTES ESTIL...

This manual is also suitable for:

Em1-500EhttEhtt-l

Table of Contents