Max Startups Full
Max Startups Rate
Unauthenticated Access to
Serial Ports
CONFIGURE MENU
The number of connections pending authen-
tication before all new connections are refused.
Required full: int (minimum = 1; default = 100)
This is the percentage rate at which new con-
nections are refused once the Max Startups value
is reached. The rate is increased to 100% at Max
Startup Full.
Required rate: int (minimum = 1; maximum = 100;
default = 30),
The rate at which connections are refused ran-
domly begins at max startup rate and increases
linearly until the number of connections pending
authentication reach max startups full, in which
case 100% of new connections are refused.
This is the feature Enable/Disable button.