Relocation; Disposal; For The Installer; About The Box - Daikin VRV system FXMQ200AXVMB Installation And Operation Manual

Hide thumbs Also See for VRV system FXMQ200AXVMB:
Table of Contents

Advertisement

9

Relocation

Contact your dealer to remove and reinstall the entire unit. Moving
units requires technical expertise.

For the installer

11

About the box

Keep the following in mind:
▪ At delivery, the unit MUST be checked for damage and
completeness. Any damage or missing parts MUST be reported
immediately to the claims agent of the carrier.
▪ Bring the packed unit as close as possible to its final installation
position to prevent damage during transport.
▪ Prepare in advance the path along which you want to bring the
unit to its final installation position.
11.1

Indoor unit

11.1.1
To remove the accessories from the
indoor unit
1 Remove the accessories from the side of the unit. Air outlet
flange is placed under the indoor unit.
a
b
a
Installation and operation manual
b
General safety precautions
c
Washers for hanger bracket
d
Screws for duct flanges (M5×12)
e
Hexagon head bolt (M10×40)
f
Attached piping with sealing
g
Tie wrap
h
Spring washer
i
Air outlet flange (under the indoor unit)
12

Unit installation

12.1

Preparing the installation site

12.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
INFORMATION
Equipment meets the requirement for commercial and
light-industrial location when professionally installed and
maintained.
FXMQ-A
VRV system air conditioner
3P701545-1 – 2022.07
c
d
e
f
g
h
i
49×
10

Disposal

NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
NOTICE
If the equipment is installed closer than 30  m to a
residential location, the professional installer MUST
evaluate the EMC situation before installation.
CAUTION
This equipment is NOT intended for use in residential
locations and will NOT guarantee to provide adequate
protection to radio reception in such locations.
CAUTION
Appliance NOT accessible to the general public, install it in
a secured area, protected from easy access.
This unit, both indoor and outdoor, is suitable for
installation
environment.
▪ Drainage. Make sure condensation water can be evacuated
properly.
▪ Ceiling insulation. When conditions in the ceiling exceed 30°C
and a relative humidity of 80%, or when fresh air is inducted into
the ceiling, then additional insulation is required (minimum 10 mm
thickness, polyethylene foam).
▪ Protective guards. Make sure to install protective guards (field
supply) on the suction and discharge side to prevent somebody
from touching the fan blades or heat exchanger.
▪ Spacing. Mind the following requirements:
A
Minimum distance to the floor: 2.5 m to avoid
accidental touching
a
Ceiling
b
Floor surface
c
Maintenance space
d
Minimum required space of installation
e
Minimum space for allowing downward slope 1/100 for
drainage
▪ Discharge grille. Minimum requirement installation height of
discharge grille ≥1.8 m.
9 Relocation
in
a
commercial
and
light
c ≥650
a
b
Installation and operation manual
industrial
(mm)
11