Daikin FXMQ40MVE Installation Manual

Daikin FXMQ40MVE Installation Manual

Vrv system inverter air conditione
Hide thumbs Also See for FXMQ40MVE:

Advertisement

SYSTEM Inverter Air Conditioners
MODELS
Ceiling-mounted Duct type
FXMQ40MVE
FXMQ100MVE
FXMQ50MVE
FXMQ125MVE
FXMQ63MVE
FXMQ200MVE
FXMQ80MVE
FXMQ250MVE
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER
ALGUNA DUDA.
PRIMA DELL'INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
∆ΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ Ο∆ΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ÏÅÐÅÄ ÍÀ×ÀËÎÌ ÌÎÍÒÀÆÀ ÂÍÈÌÀÒÅËÜÍÎ ÎÇÍÀÊÎÌÜÒÅÑÜ Ñ ÄÀÍÍÛÌÈ
ÈÍÑÒÐÓÊÖÈßÌÈ. ÑÎÕÐÀÍÈÒÅ ÄÀÍÍÎÅ ÐÓÊÎÂÎÄÑÒÂÎ Â ÌÅÑÒÅ, ÓÄÎÁÍÎÌ ÄËß
ÎÁÐÀÙÅÍÈß Â ÁÓÄÓÙÅÌ.
INSTALLATION MANUAL
FXMQ40MAVE
FXMQ100MAVE
FXMQ50MAVE
FXMQ125MAVE
FXMQ63MAVE
FXMQ200MAVE
FXMQ80MAVE
FXMQ250MAVE
FXMQ200MAV7
FXMQ250MAV7
English
Deutsch
Français
Español
Italiano
ëëçíéêÜ
Nederlands
Portugues
óññêèé

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FXMQ40MVE

  • Page 1 INSTALLATION MANUAL English SYSTEM Inverter Air Conditioners Deutsch MODELS Français Ceiling-mounted Duct type FXMQ40MVE FXMQ100MVE FXMQ40MAVE FXMQ100MAVE FXMQ200MAV7 FXMQ50MVE FXMQ125MVE FXMQ50MAVE FXMQ125MAVE FXMQ250MAV7 Español FXMQ63MVE FXMQ200MVE FXMQ63MAVE FXMQ200MAVE FXMQ80MVE FXMQ250MVE FXMQ80MAVE FXMQ250MAVE Italiano ëëçíéêÜ READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
  • Page 2 3P109591-1E...
  • Page 3: Table Of Contents

    VRV SYSTEM Inverter Air Conditioners Installation manual CONTENTS Otherwise, this may lead to an accident due to oxygen defi- ciency. 1. SAFETY PRECAUTIONS..........1 • Be sure to use only the specified parts and accessories for 2. BEFORE INSTALLATION..........2 installation work.
  • Page 4: Before Installation

    • Where corrosive gas like sulfurous gas exists. (Cop- CAUTION per tubing and brazed spots may corrode which could • Install drain piping according to this installation manual to eventually lead to refrigerant leaks.) ensure good drainage, and insulate the piping to prevent •...
  • Page 5: Selecting Installation Site

    SELECTING INSTALLATION SITE OPTIONAL ACCESSORIES • These are two types of remote controllers: wired and wire- Please attach additional thermal insulation material to the unit less. Select a remote controller according to customer body when it is believed that the relative humidity in the ceiling request and install in an appropriate place.
  • Page 6: Preparations Before Installation

    PREPARATIONS BEFORE INSTALLA- Installation example TION (1) Relative positions of indoor unit and suspension bolt. Ceiling slab (Refer to Fig. 2) nchor FXMQ40 · 50 · 63 · 80 · 100 · 125M(A)VE Long nut or turn-buckle Suspension bolt Suspension bolt (× 4) Indoor unit Note) ll the above parts are field supplied.
  • Page 7: Refrigerant Piping Work

    REFRIGERANT PIPING WORK ster oil or ether oil. 〈For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.〉 〈Execute heat insulation work completely on both sides of the gas piping and the liquid piping. Otherwise, a water leakage can result sometimes.〉...
  • Page 8: Drain Piping Work

    (1) Carry out the drain piping. CAUTION FXMQ40-125M(A)VE CAUTION TO BE TAKEN WHEN BRAZING REFRIGER- ANT PIPING Do not use flux when brazing refrigerant piping. Therefore, Attached drain hose use the phosphor copper brazing filler metal (BCuP-2: JIS Z Bottom of unit 3264/B-Cu93P-710/795: ISO 3677) which does not require flux.
  • Page 9: Electric Wiring Work

    FXMQ40 · 50 · CAUTION 0.100 63M(A)VE • Drain piping connections FXMQ80M(A)VE 0.160 Do not connect the drain piping directly to sewage pipes that smell of ammonia. The ammonia in the sewage might enter Max. 242 FXMQ100M(A)VE 0.270 the indoor unit through the drain pipes and corrode the heat Min.
  • Page 10 same locations outside of the unit, separating them by at least 50mm, otherwise electrical noise (external static) could FXMQ200 · 250M(A)VE, MAV7 cause mistaken operation or breakage. Remote controller wiring (*) [ PRECAUTIONS ] (Field wiring) 1. Use round crimp-style terminals for connecting wires to the Transmission Power supply power supply terminal block.
  • Page 11 9-2 WIRING EXAMPLE 3. When including BS unit • Fit the power supply wiring of each unit with a switch and Power Power Outdoor unit fuse as shown in the drawing. supply supply 220-240V 220-240V Control box IN/D OUT/D COMPLETE SYSTEM EXAMPLE (3 SYSTEMS) 50Hz 50Hz BS unit...
  • Page 12: Field Setting

    (4) Add remote control 2 (slave) to the terminal block for (position) No. to “01” for FORCED OFF and “02” for ON/ remote controller (P ) in the control box. OFF OPERATION. (FORCED OFF at factory set) (There is no polarity.) (Refer to Fig. 3 and 8-3.) 11.
  • Page 13 3P258319-6F EM02A083G (1406) FS...