4) Rx Test Specification

TEST ITEM
CONDITION
RX Sensitivity
216.05MHz
223.50MHz
250.05MHz
223.50MHz
NARROW
223.50MHz
RX Distortion
WIDE
NARROW
RX S/N
WIDE
NARROW
Squelch
223.50MHz
Sensitivity
Indication 02
S Meter
223.50MHz
1KHz
3.5KHz/DEV
AF Output
223.50MHz
CTCSS
WIDE
Sensitivity
NARROW
DCS Sensitivity
WIDE
NARROW
Drain Current
223.50MHz
Power
223.50MHz
Off
Current
Howling
223.50MHz
52
ADJ STANDARD
TEST STANDARD
Less than -7dBu
Less than -6dBu
Less than -8dBu
Less than -7dBu
Less than -3dBu
Less than -2dBu
Less than -8dBu
Less than -7dBu
Less than+6dBu
Less than +7dBu
Less than 4%
Less than 5%
More than 40dB
More than 38dB
More than 34dB
More than 32dB
Squelch Open
Squelch Open
Squelch Close
Squelch Close
appears at
All
All
appears at
20dBu
25dBu
More than 2W
More than 2W
Open at
Open at
500Hz/DEV
500Hz/DEV
Open at
Open at
250Hz/DEV
250Hz/DEV
Opens when Test
Opens when Test
Equipment
is in
Equipment
Tx
Tx
Opens when Test
Opens when Test
Equipment
is in
Equipment
Tx
Tx
Less than 0.65A
Less than 0.65A
Less than 10mA
Less than 10mA
Don't occur
Don't occur
NOTE
12dBSINAD
AM 10dB S/N
SSG OUT PUT 30dBu
SSG OUT PUT 30dBu
0.3~3KHzBPF OFF
SSG Output -10dBu
SSG Output OFF
Decrease
SSG level
and
decrease S Meter
level
SSG Output 30dBu
SSG Output 0dBu
88.5Hz
255 code
is in
255 code
is in
MAX VR
Power Off
SSG Output 60dBu
MOD OFF MAX VR