Lexicon
6.2.1 Acknowledge
6.2.1.1 Packet Description
6.2.1.2 Data Description
Command:
DataType:
6.2.2 No Acknowledge
6.2.2.1 Packet Description
6.2.2.2 Data Description
Command:
DataType:
ErrorCode:
DataType:
6.3 Host Initiated Command Packets
The MC-8 serial communication protocol has been designed to respond to the following commands as
described below. Each command is transmitted to the MC-8 with the identified parameters. If the
command is successfully received and processed by the MC-8, the unit will respond with the described
response packet or action.
6.3.1 Reset Unit
Commands the MC-8 to soft reset.
Application Header:
Command
Data Count
Application Data:
Data[0]
Valid MC-8 command as defined in the Command Codes table
(Appendix A page
35).
Application Header:
Command
DC_NACK
Data Count
2
Application Data:
Data[0]
Command
Data[1]
ErrorCode
Valid MC-8 command as defined in the Command Codes table
(Appendix A page
35).
Error code as defined in the Error Codes table
MC-8 Serial Communications Protocol
DC_ACK
0xE0
1
0x01
Command nn
0xE1
0x02
nn
nn
(Appendix B page
36).
11