Isuzu AA-6HK1T Workshop Manual page 204

Industrial diesel engine
Table of Contents

Advertisement

AMMETER
A
LAMP (24V)
B
L
R
ALTERNATOR
V
VOLTMETER
Current output
1. Operate the alternator at minimum speed.
2. Close switch 1. Check that the lamp lights.
3. Set the load resistor to its maximum resistance
(minimum current).
4. Close switch 2.
5. Increase the alternator speed to a constant 5,000
-1
min
.
6. Adjust the load resistor for maximum current output.
7. Allow the alternator to run for 15 minutes. Output
should increase as alternator temperature increases.
8. Once again, adjust the load resistor for maximum
current output.
The maximum current output must equal the
specified value. If it does not, the alternator must be
rechecked.
Alternator output:
50 amp/27 volt/5,000min
SWITCH 1
SWITCH 2
(3W MAX.)
BATTERY
(24V)
LOAD
RESISTOR
-1
STARTING AND CHARGING
6D3–9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bb-6hk1t