Setting the Test Cycle
With the door CLOSED and the dishwasher switched OFF
1. Press and hold down Sw2 & Sw5.
2. Press Sw0 to switch the appliance on.
3. Hold down Sw2 & Sw5 for about 5 seconds until the buzzer sounds.
After 5 seconds, the display will show [C O L] (abbreviation for "collaudo" = test) & [P 1 3]
alternately to show the status of the test cycle.
4. Press Sw5 to start the cycle
The display will show [C 0 L] for the entire duration of the cycle.
During the Cycle:
If the door is opened, the diagnostics cycle is interrupted but not cancelled.
If the dishwasher is switched off by pressing Sw0, or in case of a power failure, the diagnostics
routine is interrupted, but not cancelled; when the dishwasher is switched on again, the cycle
resumes normally from the point at which it was interrupted.
To cancel the diagnostics cycle currently being performed, press Sw5 and hold down for 5
seconds.
At the end of the cycle, the display shows [ - - - ] (three central segments) to indicate the end of
the programme and the appliance exits the test procedure automatically.
After a further 5 seconds, the display shows the last programme performed (before the test
cycle), e.g. [P . 3].
Press Sw0 to switch the appliance off.
NOTE:- The safety devices are operative during the diagnostics cycle; in case of a malfunction, the
relative ALARM code is shown in the DISPLAY.