REGENERATION CYCLE
Each time the regeneration procedure is performed, the chambers are drained completely (about 230ml
of water)
• Cycle counting for "special" regeneration is performed by the electronic control system and is
based on the number of fill phases rather than on the actual number of cycles; this makes the
process independent of the number and type of programmes performed.
• Calculation of the number of cycles is based on a programme with 5 fill phases.
• Modification of the level of regeneration automatically results in regeneration being carried out in
the subsequent cycle, irrespective of the number of fill phases performed previously.
• With the new board, regeneration is always performed in the first cycle irrespective of the level of
regeneration selected. (Level [L . O] – no regeneration).
• If level [ 0 ] is selected, regeneration does not take place and the Salt LED remains off.
SELECTING REGENERATION LEVEL
With the Dishwasher switched On
1. Press and hold down Sw1 & Sw4 simultaneously.
After about 5sec the Display indicates [L . 4] (L flashing).
2. To modify the level of regeneration, press Sw4 repeatedly within 5sec.
The Display [L . .] indicates the corresponding regeneration level in sequence every time the key is
pressed.
All remaining keys are disabled
Five seconds after pressing Sw4 for the last time, the selected regeneration level is stored in memory
and the dishwasher returns to the previous condition (Programme Selection mode).
SAFETY FEATURES - CONTROLS - ALARMS
Dishwashers fitted with electronic control systems feature a series of safety devices designed to
protect the appliance whether it is switched on or off.
SYSTEM DEFINITION
The electronic control provides that, if one of the following safety features should intervene, a Time-
Out immediately interrupts the washing cycle
The user is warned of the abnormal situation by a visual signal on the display panel (in the form of a
code) and by the buzzer.
SAFETY FEATURE
NTC sensor short-circuited
NTC sensor: open circuit
Heating Time-out
Anti-flooding
Water fill Time-out
Pressure switch "EMPTY" Time-out
Water drain Time-out
Motor inoperative Time-out
Motor Triac short-circuited
Page 18 DW 107
ALARM
AL1
AL2
AL3
* AL4
AL5
* AL5
AL6
AL7
AL8
* Automatic Cycle Reset
Automatic Cycle
Reset
NO
NO
NO
YES
NO
YES
NO
NO
NO
Interruption
of Cycle
YES
YES
YES
YES
YES
YES
YES
YES
YES