COMPONENT TESTING
In order to facilitate testing of the components, a Test Procedure has been created showing the contacts
to which the probes of the tester should be connected and the reading for each component.
To gain access to the electronic control board and the harness connectors, dismantle the door.
• Remove the harness connectors from the control board, connect the probes of the tester to the points
indicated in the table and compare the actual reading with the theoretical value.
• If preferred components that are easily accessible can be tested directly on the component. (Wiring
connections are excluded)
COMPONENTS
POWER CABLE &
ON/OFF SWITCH
INTEGRATED DISPENSER
HEATING ELEMENT
(+ SAFETY THERMOSTAT)
DOOR MICROSWITCH
TACHYMETRIC SENSOR
RINSE-AID SENSOR
SALT SENSOR
TEMPERATURE SENSOR
RESET SOLENOID
DRAIN MOTOR
WASHING MOTOR
REGENERATION SOLENOID
FILL SOLENOID
(+ ANTI-FLOODING device)
PRESSURE SWITCH
NOTE: - *Measurement points L - N refer to the pins on the plug on the service cord.
REGENERATION CYCLE
The level of regeneration can be selected electronically with 10 regeneration levels.
«DISPLAY»
LEVEL
AUTONOMY
[L . 0]
[L . 1]
[L . 2]
[L . 3]
* [L . 4]
[L . 5]
[L . 6]
[L . 7]
[L . 8]
[L . 9]
* L.4 Standard factory setting
CONTACTS
* L - C4*
* N - A1
C1 - C2
C3 - A2
C3 - C4
C5 - C6
D1 - D2
E4 - E5
E2 - E3
E1 - D3
E1 - F1
E1 - F3
E1 - F4
E1 - F5
E1 – F7
WASHING CYCLE
REGEN.
No regeneration
8 cycles
at 9th cycle
6 cycles
at 7th cycle
4 cycles
at 5th cycle
3 cycles
at 4th cycle
2 cycles
at 3rd cycle
1 cycle
at 2nd cycle
0 cycles
Every cycle
CORRECT VALUE
0 Ω
0 Ω
1500 Ω ± 8%
25 Ω ± 8%
0 Ω
135 Ω ± 8%
INFINITY
0 Ω
INFINITY
0 Ω
6.030 Ω ± 8%
1.010 Ω ± 8%
700 Ω ± 8%
610 Ω ± 8%
70 Ω ± 8%
50 Ω ± 8%
5.100 Ω ± 8%
3.800 Ω ± 8%
INFINITY
0 Ω
FILL
HARDNESS OF WATER
PHASE
PPM (Parts per million)
-
40
30
20
15
10
5
1
NOTES
With ON/OFF key pressed
OK
Connected in series
(2100 W)
With door CLOSED
OK
With Rinse-Aid
Without Rinse-Aid
With Salt
Without Salt
(at 20 ºC)
(at 65 ºC)
(if the RESET solenoid is
interrupted)
OK
OK
OK
OK
Connected in series
EMPTY position (1-2)
FULL position (1-3)
0 – 80
81 – 140
141 – 200
201 – 300
301 – 400
401 – 500
501 – 600
601 – 700
701 – 800
801 – 900
Page 17 DW 107