PART 1
Press Sw1
b) SERVICE CUSTOMIZATION – The display will show:
DGT_1 [ A ] letter
DGT_2 [ ] off
DGT_3 [ . ] number [ 0, 1, 2, 3 ] (supplementary options)
Example: [ A . 0 ] = no supplementary options (standard setting).
Press Sw1 again
c) NUMBER OF WASHING CYCLES - the Display shows the number of washing cycles in two
phases:
DGT_1 [C ] letter (cycles)
DGT_2 [ . ] number (thousands)
DGT_3 [ . ] number (hundreds)
Press Sw1 again
DGT_1 [ ] off
DGT_2 [ . ] number (tens)
DGT_3 [ . ] number (units)
The total number of cycles is indicated by the sum of the two readings. Example: [C 1 5 ] + [. 1 3 ] =
1513 cycles.
Press Sw1 again
d) The LAST ALARM CONDITION is displayed as follows:
DGT_1 & DGT_2 [ A L] (alarm)
DGT_3 [ - ] number [ 1, 2, 3, 4, 5, 6, 7, 8 ] (alarm code)
Example: [ A L 4 ] Anti-flooding alarm
Press Sw1 again to pass to the Component Diagnostics procedure
PART 2
e) COMPONENT DIAGNOSTICS: The display shows:
DGT_1 & DGT_2 [C d ] two letters
DGT_3 [ - ] number [ 0, 1, 2, 3, 4, 5, 6 ] (Reference number)
Press Sw1 repeatedly
It is now possible to check the operation of each electrical component in sequence. The relative codes
are shown on the display.
DISPLAY
Water Fill Solenoid Valve
[ C d 0]
Detergent/Rinse-Aid Dispenser
[ C d 1 ]
Washing Motor (Lower Spray Arm)
[ C d 2 ]
Heating Element
[ C d 3 ]
Re-set Solenoid Valve + Fan Motor
[ C d 4 ]
Regeneration Solenoid Valve
[ C d 5 ]
Drain Motor
[ C d 6 ]
End of Test
[ C d 6 ]
Page 22 DW 107
COMPONENTS TESTED
PRESS TO
TIME-OUT
ADVANCE
60 sec
Sw1
60 sec
Sw1
60 sec
Sw1
20 sec
Sw1
60 sec
Sw1
60 sec
Sw1
60 sec
Pause 
Exit
Sw0