INSTALLATION
DANGER:
FIRE AND
EXPLOSION
HAZARD
NEVER use an open flame to
check for gas leaks. Fire and
explosion may result.
IMPORTANT:
All pipe joints must be checked
for leaks before lighting. Leak
checks should be performed
with a soap and water solution.
WARNING:
FIRE HAZARD
This griddle is supplied with a
gas pressure regulator.
Failure to properly install the
supplied regulator will result in
an extremely hazardous
condition.
Flow arrow stamped on body of
regulator must point toward the
griddle.
Regulator adjusting screw and
vent hole must point UP.
IMPORTANT:
Verify fuel gas type. If the
available fuel does not match
the nameplate specification,
exchange the griddle for the
correct type. DO NOT attempt
to modify a unit in the field to
accept a different fuel.
IMPORTANT:
Avoid damage to the regulator:
if the gas supply piping system
is pressure tested at pressures
exceeding 1/2 psig (3.45kPa),
the griddle must be isolated
or disconnected from the gas
piping system for the duration
of the test.
INSTALLING THE GRIDDLE
Refer to the nameplate. Verify the fuel type and pressure, which must
match the nameplate specifications. Connecting the griddle to the
wrong fuel type and/or pressure will compromise the safety and/or
performance of the appliance.
The griddle must be placed in its final operational position and
leveled front-to-back and side-to-side, with a spirit level, prior to
beginning the gas piping installation. Re-check the level of the unit
at the conclusion of the gas piping installation.
Each gas griddle is supplied with a separate gas pressure regulator.
The supplied regulator must be used, and must be installed on the
manifold pipe protruding from the rear of the griddle. Ensure that the
regulator is installed such that the flow arrow stamped on the body of
the regulator points toward the griddle. Failure to properly install the
supplied regulator will result in an extremely hazardous condition.
A moisture trap (drip leg) consisting of a tee, 4" nipple pointing down,
and cap must be installed upstream of the gas pressure regulator.
A manual gas shut-off valve may be required by local codes and
is, in any case, strongly recommended. The shut-off valve must
be installed between the gas supply piping and the gas pressure
regulator.
It is the responsibility of the gas piping installer to identify the code
requirement for a shut-off valve.
Shut-off valves, moisture trap and all associated piping must be
supplied by the gas piping installer.
PRESSURE
ADJUSTMENT
(under cap)
SUPPLIED
REGULATOR
GAS
SHUT-OFF
VALVE*
GAS
SUPPLY*
Fig. 2 Gas Supply Piping
6
VENT
B A
C K
O F
U N
I T
O W
F L
DRIP LEG*
* by others
IL2193