HIKVISION DS-K3G501LX Series User Manual page 23

Tripod turnstile
Table of Contents

Advertisement

DS-K3G501LX Series Tripod Turnstile User Manual
Note
You will need to prepare the 14AWG power cable to connect the AC power input to power
supply.
The fire alarm module, face recognition module and exit button use the same grounding
interface.
Gate opens at the entrance/exit: connect to BTN1/BTN2 and GND.
The two 12 V power output interfaces are the power supply for face recognition terminals,
which is only supported by the product with power switch.
For models with power adapter, the power supply for face recognition modules is not contained
in package
Figure 4-3 General Wiring of Pedestal with Power Switch
Figure 4-4 General Wiring of Pedestal with Power Adapter