FSA Operating Manual Your FSA at a glance Overview ungauged device Name Material funnel Drawer Cold appliance plug Type label with serial number Ethernet port USB port LCD display Integrated printer Page 2...
Overview gauged device Name Material funnel Drawer Gauging seal Cold appliance plug Type label with serial number Ethernet port USB port LCD display Integrated printer Page 3...
FSA Operating Manual Overview top of the device - ungauged/gauged Name On/Off button Gauging badge (only for gauged devices) Material funnel LCD display Integrated printer Device name Page 4...
The menus The device has three different menus: home, measuring window and main menu: Home menu Name Main menu Time and date Version number Measuring window Page 5...
Page 6
FSA Operating Manual Measuring window ungauged device Name Switching off Main menu Home Starting the measurement Product selection Supplier management Printing the current measurement (see "5.4 Printing measured values") Time and date Note to empty the drawer Supplier information Material temperature...
Page 7
Measuring window gauged device Name Switching off Main menu Home Starting the measurement Product selection Supplier management Printing the current measurement (see "5.4 Printing measured values") Time and date Note to empty the drawer Gauging information for selected product Supplier information Material temperature Hectolitre weight Material moisture...
Page 8
FSA Operating Manual Main menu Name Switching off Main menu Home Language Memory location Settings Gauging (only accessible for gauging authority) Information Memory User data Administrator Page 8...
Table of contents Your FSA at a glance ��������������������������������������������������������������������� 2 Overview ungauged device .................2 Overview gauged device ................3 Overview top of the device - ungauged/gauged ..........4 The menus ....................5 1� Introduction ������������������������������������������������������������������ 12 Information about this operating manual ........12 Limitation of liability ..............12 Symbols used in this manual ............12...
Page 10
FSA Operating Manual 5� The measuring process ������������������������������������������������� 19 Preparing a measurement ............19 Taking a measurement ...............19 Managing supplier data .............20 Printing measured values ............21 Viewing all measuring data (data storage) ........23 Deleting all measuring data (data storage) (only ungauged) ..23 6�...
Page 11
11� Cleaning and maintenance ������������������������������������������ 37 11.1 Care instructions ................37 11.2 Cleaning the device ..............37 11.3 Replacing the printer paper roll ..........38 11.4 Checking the calibration ............39 12� Faults ����������������������������������������������������������������������������� 41 12.1 Possible error messages .............43 12.2 Transporting the device ..............45 12.3 Storing the device ..............46 12.4...
Introduction Information about this operating manual This operating manual is designed to enable you to use the FSA grain moisture analyser safely and effectively. It is part of the device, has to be stored nearby and must be easily accessible to users at all times.
FSA Operating Manual For your safety The device complies with the following European directives: • Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) • Electrical equipment (Low Voltage Directive, LVD) • Electromagnetic compatibility (EMC) • Machinery The device corresponds to state-of-the-art technology. However, it is still associated with a number of residual hazards.
Danger from electric current WARNING Electric shock Danger to life due to electric shock when operating with a defective mains cable or defective device. ► Disconnect the device from the power supply and secure it against being switched on again. Observe the following safety instructions to avoid hazards from electric current: •...
Making sure that all of the components have been included Make sure that all of the components have been included by checking the package contents against the following list: • FSA incl. transport lock • drawer • Schuko cable (CEE 7/7) •...
• Before each transport, insert the screw again (figure 3). • It is important that the screwing is done without any force. It should be screwable without much effort. » If this is not possible, please contact Schaller Messtech- nik GmbH. Setting up the device Note the following: •...
FSA Operating Manual Using the device - Basics Inserting the drawer • Make sure that the transport lock has been removed (figure 4). • Slide the drawer into the device (figure 5). Plugging in the device Make sure that the socket you want to use has the same electrical voltage as described on the name plate of the device.
The measuring process Preparing a measurement To do so: The display has to show the measuring window (figure 8). Press the button Product Now select the required product type from all the types stored in the device (figure 9). » A measuring process without selecting a product is not possible! Before starting the measurement, you can create and select different supplier names...
FSA Operating Manual ATTENTION Crushing hazard Risk of crushing due to the movement of the flap in the material funnel ► Keep any parts of the body away from the material funnel of the device. Information - Measuring accuracy To increase the measuring accuracy, take three measurements of the same material.
5.3.2 Selecting a supplier • Select the required supplier from the list of stored suppliers (figure 14). » Select the "empty supplier" if no supplier data should be displayed. • Confirm by pressing Ok 5.3.3 Modifying supplier data • Select the required supplier from the list of stored suppliers. •...
Page 22
FSA Operating Manual 5.4.1 Gauged device • Due the calibration law, a manda- tory printout is made after verified measurements. • The current measuring value is printed out (printout figure 18). 5.4.2 Ungauged device • Press the button Print • The current measuring value is printed out (printout figure 19).
Viewing all measuring data (data storage) To do so: A measurement was carried out. • Press the button Menu » The display will now show the main menu (figure 20). • Press Memory » The display will now show the previous mea- suring data (figure 21).
! Only for calibration and checking of the device ! reference ! Only for calibration and checking of the device ! On request, Schaller Messtechnik GmbH can develop customer-specific characteristic curves for special product types. It is also possible to subsequently enter optionally available characteristic curves into the device.
How moisture is defined The device measures and shows a material’s moisture content. The moisture content readings it displays are calculated in relation to the material’s overall mass: Mass of the sample with average moisture content Mass of the sample with zero moisture content %WG: Moisture content (in accordance with EN ISO 665:2001-02-01, EN ISO 712:2010-04-01 and EN ISO 6540:2010-07-15)
FSA Operating Manual Note regarding tolerances for deviations For calibrated devices, the responsible gauging office (in Austria the BEV Bundesamt für Eich- und Vermessungswesen) stipulates tolerance variations, so-called calibration error limits and operating management error limits for the measurement of calibrated material types.
Using the LogMemorizer program To do so: USB stick with LogMemorizer software and network cable required Installing / opening the program Insert the USB stick with the LogMemorizer program into the USB port on your computer. Open the setup application. Follow the installation instructions.
Page 28
Import most recent manual log (for importing the most recent manually saved log) (figure 28). Name Import all manual logs Import most recent manual log » The measuring values saved on the FSA will now be sent to your computer. Page 28...
Data access via REST interface To do so: The REST interface has been activated on the device and is connected to the network. Determining the network address of the device • When connecting to the network, your device should automatically be assigned a network address.
FSA Operating Manual Checking the device's status • Open the main menu. » Press the button Menu • Press the button Information » The display will now show the following information: Name User (see "10.5 My device") Serial number Gauging status...
10. Configuring the device 10.1 Selecting a language Press the button Menu » The display will now show the main menu. Press the button Language » The display will now show all selectable languages. Navigate through the selectable languages using the arrow keys Select your desired language.
FSA Operating Manual 10.3 Selecting °C/°F Press the button Menu » The display will now show the main menu. Press the button Settings » The display will now show the settings. Press the button Temperature » Now you can select the desired temperature scale.
10.6 Log file • Press the button Menu » The display will now show the main menu. • Press the button Settings » The display will now show the settings. • Press the button Log file 10.6.1 Log types Three different log types can be selected: Info ...
10.7 Update There is the possibility to perform an update of the software or the product types. If you receive an update file from Schaller Messtechnik, the file has to be copied into the main directory via USB stick. Plug in the USB stick containing the update into the device.
"10.9.1 Setting the offset"). Confirm your changes by pressing Save » The settings have been saved and you are back in the product list. For changes of the calibration values, Schaller Messtechnik GmbH doesn't assume any li- ability! Page 35...
Page 36
FSA Operating Manual 10.9.1 Setting the offset By changing the offset, the displayed measurement values can be adapted to other norms/standards. The displayed measuring value is corrected by the entered offset. Example: An offset of 1.5 % applied to a measurement value of 10.0 % results in a displayed measurement value of 11.5 % in the selected range.
11. Cleaning and maintenance Regularly cleaning and maintaining the device will ensure that it will have a long service life and stay in good condition. 11.1 Care instructions • Do not leave the device out in the rain. The device is not waterproof. •...
FSA Operating Manual Drawer • Clean the drawer with dry compressed air, a cloth or a soft brush. Interior of the device • Before the cleaning, remove the drawer. » If necessary, tilt the device slightly forwards and backwards. • Remove possible residues or dirt by blowing dry compressed air through the opening for the drawer or through the material funnel on the top of the de- vice.
11.4 Checking the calibration The device’s calibration should be checked regularly. To do so: Optionally available test medium required • Press the button Menu » The display will now show the main menu. • Press the button Settings » The display will now show the settings. •...
Page 40
FSA Operating Manual Confirm the test by pressing Ok » Now you are back in the device test menu. 11.4.2 Scale test Press the button Scale » The device now automatically determines the value without test weight (tare value) (figure 40).
» Now you are back in the device test menu. 12. Faults If the measures listed below fail to remedy any faults or if the device has faults not listed here, please contact Schaller Messtechnik GmbH. Fault Cause Remedy Measuring error...
Page 42
LogMemorizer program. Measuring device The overvoltage and tempera- Disconnect the device from does not boot any ture protection of the FSA may the power supply and wait more. have been triggered for about 4 hours. After that the overvoltage protection should have been reacti- vated.
12.1 Possible error messages If the measures listed below fail to remedy any faults or if the device has faults not listed here, please contact Schaller Messtechnik GmbH. Fault Cause Remedy Sensor calibration Heavy contamination in the Thoroughly clean the interior...
Page 44
Fault Cause Remedy Defective opening Multiple blockage of the Thoroughly clean the interior of opening the FSA through the mate- rial opening (see "11.2 Cleaning device"). If the problem re- curs, contact Schaller Messtech- nik GmbH. Defective lid Multiple blockage of the lid...
Insert a new paper roll. paper. Printer is offline Communication problem Restart the device. If the prob- between the printer and the lem recurs, contact Schaller FSA. Messtechnik GmbH. Touch calibration Incorrect use of the touch Restart the device and repeat...
FSA Operating Manual If your device has been delivered with an additional overpack (bigger cardboard box), always ship the device packed in both cardboard boxes. Follow the instructions on the transport label on the packaging. 12.3 Storing the device Store the device under the following conditions : •...
13. Device information 13.1 CE declaration of conformity _______________ KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY Name/ Adresse des Herstellers: Schaller Messtechnik GmbH Max-Schaller-Straße 99 Name/ address of manufacturer: A – 8181 St. Ruprecht Produktbezeichnung: Schaller Product designation: Typenbezeichnung: Type designation: Messgerät zur Bestimmung des Wassergehalts in...
Page 48
FSA Operating Manual EN ISO 12100:2011 Allgemeine Gestaltungsleitsätze - Risikobeurteilung und EN ISO 12100:2013 Risikominderung Safety of machinery - General principles for design - Risk as- sessment and risk reduction EN ISO 13857:2020-04 Sicherheit von Maschinen - Sicherheitsabstände gegen das Erreichen von Gefahrstellen mit den oberen Gliedmaßen und...
Page 49
_______________ DECLARATION OF CONFORMITY Schaller Messtechnik GmbH Name/ address of manufacturer: Max-Schaller-Straße 99 A – 8181 St. Ruprecht Product designation: Schaller Type designation: Product description Measuring instrument for determining the water content in foodstuffs The designated product is in conformity with the following directives: Electromagnetic Compatibility Regulations 2016 Great Britain •...
Page 50
FSA Operating Manual EN ISO 12100:2011 Safety of machinery - General principles for design - Risk EN ISO 12100:2013 asassessment and risk reduction EN ISO 13857:2020-04 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs...
13.2 Technical data 13.2.1 General Display resolution 0.1 °C temperature 0.1 kg/hl hectolitre weight Operating temperature +10 °C to +50 °C Storage temperature +3 °C to +50 °C Temperature sensor Infrared (contactless) Temperature compensation automatic Sample quantity approx. 450 ml Power supply 100-240 VAC 1A, 50-60 Hz Plug...
Page 52
Schaller Messtechnik develops, produces and sells professional moisture meters and turnkey solutions. Schaller Messtechnik GmbH Max-Schaller-Straße 99, A - 8181 St. Ruprecht an der Raab Tel +43 (0)3178 - 28899 , Fax +43 (0)3178 - 28899 - 901 info@humimeter.com, www.humimeter.com...
Need help?
Do you have a question about the FSA and is the answer not in the manual?
Questions and answers