Inspect The Network - Check And Mark Wiring Compliance - ABB CPS3200U Product Manual

Remote power system 48 vdc input, +-190 vdc output converter/limiter system
Hide thumbs Also See for CPS3200U:
Table of Contents

Advertisement

7. Inspect the Network - Check and Mark Wiring Compliance

The CPS3200U +/-190V system is classified as an A3 circuit tested according to GR-1089-CORE Issue
6. As such, each location in the network where the output is available to be touched must be
protected and marked as an A3 voltage.
Step
1.
Is accessibility to the circuit throughout the network consistent with A3 requirements?
Voltage Class
2
Is the 5-pin protector marked as a special circuit?
Does the 5-pin protector protect each pair to a level corresponding to a CommScope 3C*EW Gas tube primary pro-
3.
tector? This protector has a
700 Volts. Protectors with a lower voltage breakdown rating will be problematic.
Page 35
© 2021 ABB. All rights reserved.
General public
A 1
Restricted access
A 3
Inaccessible
Table 7-1 accessibility to continuous class –A voltage
voltage breakdown range of 265-465 Volts and an impulse spark over range of <265-
Action
Employees
Exposed
Inaccessible
Craftsperson's
Exposed
Restricted access
( Exceptions )