CHARGING INSTRUCTIONS

3-Slot Cradle LED Indicators

LED
Power On (Blue LED)
Solid blue
User LED (Green LED)
Green dimming anima-
tion
(all slots in sequence)
Flash green for 300 ms
(single slot)
Solid green (single slot)
Maintenance LED (Red LED)
Blink red, 1 quick pulse
(single slot)
Blink red, 2 quick pulses
(single slot)
Maintenance LED (Red LED)
Blink red, 3 quick pulses
(single slot)
Blink red, 4 quick pulses
(single slot)
Blink red, 5 quick pulses
(single slot)
Blink red, 6 quick pulses
(single slot)
Blink red, 7 quick pulses
(single slot)
Solid red (middle slot
only)
*. Available depending on 3-Slot Cradle model.
14
JOYA™ TOUCH 22
Status
Dock is powered.
*
Cradle application start.
Device properly locked in.
Could notify that the slot is unlocked (if programmed to use
green led to notify unlock status) or it could be controlled by
software using our SDK.
Cradle not calibrated. Usually it is notified simultaneously on
all slots. Solution: perform an "auto calibration" from DL Cra-
dle Manager. Ensure that levers are free to move.
Lever wrong position. It is open but it should be closed or
vice versa. Solution: restore the lever position (e.g.remove
the mechanical key from the slot).
FOD (Foreign Object Detection). It's a WLC error related to
metallic parts between transmitter and receiver coils. The
power transfer is suspended. Solution: remove the device
from the cradle, then remove the metallic part causing the
problem.
EOC (end of charge) timeout error. The WLC EOC signal has
been kept enabled by the terminal for too much time. Typi-
cally, it is caused by a bug in the terminal firmware. The
power transfer is disabled.
WLC generic error. The WLC system seems unstable and
unable to setup a stable power transfer within a reasonable
time. The power transfer is suspended. Solution: try to
extract the device from the cradle and to re-insert it again.
Device charging error.
Wrong daisy chain configuration error. More than two cradles
are connected in daisy chain. Solution: remove exceeding
cradles from the chain.
Firmware upgrade.