Si001170
Step
2
Cut the clamp.
Pull out the outdoor
3
heat exchanger
thermistor.
Remove the thermistor
4
ASSY.
Removal Procedure
Procedure
Outdoor heat exchanger thermistor
Removal of Electrical Box / PCB
Points
When reassembling, fix the
outdoor heat exchanger
lead wire and the harness of
the electronic expansion
valve with a clamp.
(R14896)
(R14897)
(R14898)