Removal procedure

Advertisement

Si011193
Step
Pull out the terminal
5
[B2] from the fan
capacitor (C12R).
Remove the screw and
6
remove the fan
capacitor.
Pull out the terminals
7
[2] [4] [6] [A1] [A2] from
the magnetic contactor
(K1M).
Removal Procedure
Procedure
Removal of Electrical Components
Points
Fan capacitor (C12R)
B1 B2
A1 A2
(R15401)
(R15180)
(R15181)
(R15182)
to terminal board
X2M(N): red