10 MAINTENANCE & INSPECTION
Under normal ambient and working conditions the gear unit should be checked according the following intervals. (For definition
of normal working conditions refer to the product catalogue: "Selecting Gearbox" section);
Table 6:
Item to check /replace
Every 3.000 working hours
Check for oil leakage
Check for oil level
Check oil leakage from
seal
Check Rubber buffer
Check Bearings Noise
Change Mineral Oil
Change Synthetic-PAO Oil
Change Sealing
Change Bearing Grease
Change Bearings
Check for noise Changes
NOTE:
For normal ambient conditions 70 ºC oil bath temperature should be taken as reference
* For M series Mineral oil is used unless it is differently ordered. For oil type and quantities refer to the following tables.
26
Dana Incorporated
Every 4.000 working hours
or every 6 months
x
x
x
x (Change if necessary)
x (Change if necessary)
45000
40000
35000
30000
25000
20000
15000
10000
5000
0
70 80 90 100 110 120 130 140 150 160
Oil bath temperature (Celcius)
Every 10.000 working
hours or every 3 years
x (See Below for details)
Mineral
Synthetic PAO
Synthetic PG
IMM-0019EN - Installation and Maintenance Manual
Every 25.000 working
hours
x (See Below for details)
x
x
x
x