Asus: ESC8000 G3
www.huawei.com ▪ Huawei Confidential ▪
Parameter
G5500-G560
4U (175*447*790)
Dimensions (H x W x D)
Architecture
Modular
CPU
2S + 24DIMM
Maximum CPU power
300 W
GPU
8*P100/P40
Maximum GPU power
350 W
CPU:GPU topology
Flexible 1:8/1:4 Configuration
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
RAID
RAID 0/1/10/5/50/6/60
PCIe expansion
4*PCIe x16
On-board network adapter
/
Power supply
4*2200 W hot swap, 2+2
Fan
6 hot swap, 5+1
Temperature
5°C to 35°C
Beating Points
•
The integrated design of the chassis does not support independent evolution of the CPUs and GPUs.
•
The CPU:GPU topology is fixed and cannot be flexibly configured.
•
NVMe SSD is not supported. When the SAS drive is used, it needs to occupy the extended PCIe slot.
•
The 14 fans are built-in, and there are two types of fans, which require opening the chassis for maintenance.
•
Three 1600 W power modules do not support N+N redundancy, and the capacity expansion is limited and cannot be
evolved.
•
A large number of cables are connected inside the chassis, which is inconvenient for maintenance.
48
48
Asus ESC8000 G3
3U (130.6*447*759)
Integrated
2S + 24DIMM
145 W
8*P100/P40
300 W
1:8 (1:4)
6*2.5'' SATA SSD/HDD,
Supports SAS SSD/HH D when the PCIe RAID controller card is configured.
PCH: RAID 0/1/10/5
When the PCIe RAID card is used: RAID 0/1/10/5/50/6/60
1*PCIe x8 LP card. When the 8*dual-slot cards are not fully configured, 1*PCIe
x8 FHFL card can be configured.
2*GE
3*1600 W hot swap, 2+1
The built-in fans do not support hot swap. When the fan fails, heat dissipation is
affected.