Download Print this page

Huawei FusionServer G5500 Manual page 26

Hide thumbs Also See for FusionServer G5500:

Advertisement

SuperMicro: SYS-4028GR-TXRT (NVLink)
2S + 24DIMM, CPUs with
active heat dissipation
The CPUs provide 2*PCIe x8, which
are alternatively supported with the
hard drive RAID and NVMe.
www.huawei.com ▪ Huawei Confidential ▪
Parameter
Dimensions (H x W x D)
Architecture
CPU
Maximum CPU power
GPU
Maximum GPU power
CPU:GPU topology
Hard drive
2*PCIe x8 slots
RAID
PCIe expansion
On-board network adapter
Power supply
Fan
Temperature
Beating Points
The 8 NVMe SSDs are restricted by the PCIe x8 links, and only two drives support line
rate.
The power supply capability is limited and cannot be evolved.
Active heat dissipation for the CPUs (many failure points)
The power module is integrated into the fan and has to be inserted and removed at the
same time during maintenance, which makes maintenance inconvenient.
25
25
G5500-G560
SuperMicro 4028GR-TXRT
4U (175*447*790)
4U
Modular
Modular
2S + 24DIMM
2S + 24DIMM
145 W
145 W
8*P100/P40/P4
8*P100 NVLink
350 W
300 W
1:8/1:4 flexible configuration
1:8
6*2.5'' NVMe SSD
16*2.5'' SSD/HDD (8*NVMe SSD)
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
RAID 0/1/10/5/50/6/60
RAID 0/1/10/5/50/6/60
4*PCIe x16
4*PCIe x16 (2*PCIe x8 and hard drive
RAID/NVMe alternatively supported)
4400 W hot swap, 2+2
4000 W hot swap, 2+2
6 hot swap, 5+1
8 hot swap, 7+1
5°C to 35°C
10°C to 35°C

Advertisement