suggestions may help you clear the problem. If in doubt,
contact your provider.
Flash
Fault description
code
1
Remote fault
2
Network or
configuration
fault
3
Motor 1
1
fault
4
Motor 2
fault
1
5
Left magnetic
brake fault
1195718-A
Possible action
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Recharge the batteries.
•
Check charger.
•
Contact your provider.
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Contact your provider.
•
Check cables and
connectors.
•
Check left magnetic
brake is engaged.
•
Refer to the chapter
"Pushing the mobility
device in freewheel
mode" in the user
manual of your
wheelchair.
•
Contact your provider.
Flash
Fault description
code
6
Right magnetic
brake fault
7
Module fault
(other than
remote module)
1 Configuration of the motors depending on the
wheelchair model
Troubleshooting
Possible action
•
Check cables and
connectors.
•
Check right magnetic
brake is engaged.
•
Refer to the chapter
"Pushing the mobility
device in freewheel
mode" in the user
manual of your
wheelchair.
•
Contact your provider.
•
Check cables and
connectors.
•
Check modules.
•
Recharge batteries.
•
If the chair was
stalled, reverse away
or remove obstacle.
•
Contact your provider.