zero will result in Iron targets being indicated as low conductors
and indicated with green colour.
Ground Balance
The Ground Balance of Nexus Standard MP V3 is controlled by
two rotary controls. Coarse and Fine.
The Coarse GB control is a single turn potentiometer. The Fine
control is a 10 turn potentiometer with a multi turn dial
mechanism with locking function.
These two controls are used to set the balance of the Nexus
Standard MP V3 to suit the soil conditions on any given site.
Threshold
This knob sets the level of the threshold tone. The Nexus
Standard MP V3 is meant to operate in audible Threshold level at
all times when All Metal Mode is in use.
If the VCO Multi tones are engaged permanently then it is
recommended that the Threshold level is set to silent.
Mineral Control section
The Mineral Control on Mp V3 is enabled from the Mineral Control
On/Off toggle switch on the front panel. Once this switch is turned
to On position the M.C. Fine control can be used to set the level
of resistance to high minerals of the MP V3. If the Mineral Control
toggle switch in on off position (down) the M.C. Fine control will
be disabled.
LC-MC SET control
This rotary control is used to turn on/off the RGB meter and/or to