Hardware Maintenance Manual
Diagnostic Error Code
080-196-XXX
Game Port interface test halt, error threshold
exceeded
080-197-XXX
Game Port interface test warning
080-198-XXX
Game Port interface test aborted
080-199-XXX
Game Port interface test failed, cause
unknown
086-000-XXX
Mouse Port interface Test Passed
086-001-XXX
Mouse Port interface Presence
086-032-XXX
Mouse Port interface Device controller
failure
086-035-XXX
Mouse Port interface Reset
086-040-XXX
Mouse Port interface IRQ failure
086-195-XXX
Mouse Port interface Test aborted by user
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
FRU/Action
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Flash the system and re-test. See "Flash
update procedures" on page 235
3. Go to "Undetermined problems" on page
86
1. See "Undetermined problems" on page
86
2. Flash the system and re-test. See "Flash
update procedures" on page 235
3. Replace component under function test
No action
1. Mouse
2. System board
1. Mouse
2. System board
1. Mouse
2. System board
1. Run Setup
2. Mouse
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file