Diagnostic Error Code
014-196-XXX
Parallel port test halt, error threshold
exceeded
014-197-XXX
Parallel port test warning
014-198-XXX
Parallel port test aborted
014-199-XXX
Parallel port test failed, cause unknown
014-2XX-XXX
014-3XX-XXX
Parallel port failure
015-000-XXX
USB port Interface Test Passed
015-001-XXX
USB port Presence
015-002-XXX
USB port Timeout
015-015-XXX
USB port External Loopback failure
015-027-XXX
USB port Configuration/Setup error
015-032-XXX
USB port Device Controller failure
015-034-XXX
USB port buffer
allocation failure
015-035-XXX
USB port Reset condition detected
FRU/Action
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See "Flash
update procedures" on page 235
3. Go to "Undetermined problems" on page
86
1. Go to "Undetermined problems" on page
86
2. Flash the system and re-test. See "Flash
update procedures" on page 235
3. Replace component under function test
1. External parallel device
2. System board
No action
1. Remove USB device(s) and re-test
2. System board
1. Remove USB device(s) and re-test
2. System board
1. Remove USB device(s) and re-test
2. System board
1. Flash the system. See "Flash update
procedures" on page 235
2. System board
System board
1. Reboot the system
2. Flash the system and re-test. See "Flash
update procedures" on page 235
3. Run memory test
4. System board
1. Remove USB device(s) and re-test
2. System board