UV MEDICO UV222 Industrial Technical And Installation Manual

UV MEDICO UV222 Industrial Technical And Installation Manual

Hide thumbs Also See for UV222 Industrial:

Advertisement

Quick Links

Industrial
(Filtered Far UV-C)
Technical & Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UV222 Industrial and is the answer not in the manual?

Questions and answers

Summary of Contents for UV MEDICO UV222 Industrial

  • Page 1 Industrial (Filtered Far UV-C) Technical & Installation Manual...
  • Page 2 ALWAYS KEEP THIS MANUAL WITH THE PRODUCT AND CONSULT IT REGULARLY. ATTENTION CAUTION Lumière UV émise UV Light emitted par cet appareil. from this device. Évitez de regarder Avoid looking directly directement la at the light. lampe en cours d’utilisation. IEC/TR 62471-2:2009 UV222 Industrial Technical & Installation Manual...
  • Page 3: Table Of Contents

    For information about specific adjustments, maintenance or repair jobs which are not dealt with in this manual, please contact your Product supplier or UV Medico A/S. If you suspect that the Product is damaged or detect a potential or actual danger when using the Product, immediately discontinue use of the Product and contact your supplier of the Product.
  • Page 4: Basic Safety Instructions

    Otherwise, it may result in fire, electric shock, or injury. Do not use the unit for purposes other than disinfection. The unit is designed for disinfection. Using it for any other purpose may result in unexpect- ed accidents. UV222 Industrial Technical & Installation Manual...
  • Page 5: Disclaimers

    Product or personal injury caused by non-observance by the user of the safety instruc- tions in the Manual or the applicable laws. As such UV Medico A/S shall among others not be liable for any damage or injury if the Product is used contrary to or for purposes other than its intended use, is installed, used, maintained or repaired negligently or contrary to the instructions mentioned in the Manual or on the Product;...
  • Page 6: Modification

    Product. GENERAL CHARACTERISTICS AND TECHNICAL SPECIFICATIONS UV222 Industrial has an IP66 rating, and is designed to emit Far UV-C radiation with a wavelength of 222 nm, in order to eliminate viruses, bacteria, fungi, and other pathogens, from air and surfaces.
  • Page 7: Construction

    CONSTRUCTION 300 mm [11.8 142 mm 168 mm [5.6 [6.6 R 3,5 mm [0.1 110 mm [4.3 100 mm [3.9 53 mm [2.1 113 mm [4.4 60 mm [2.4...
  • Page 8: Installation Of The Product

    CAUTION: Do not touch the glass of the lamp without gloves. Doing so may result in damage to the lamp. Oil from fingerprints will permanently etch the glass of the lamp and weaken the structure. UV222 Industrial Technical & Installation Manual...
  • Page 9: Product Installation

    300 mm [11.8 6.3. Product installation The unit must be attached to a surface by means of at least 4 mounting pins, near electrical 142 mm 168 mm wires with grounding. [5.6 [6.6 The mounting pins and surface must be strong enough to hold 4 times the weight of the unit.
  • Page 10: Change Of The Power Cable

    Remove all screws and take off the back plate. Unscrew 2x ph1 (cable blockage). Unscrew nuts for cable connections. Rewire the connector correctly. Put cable trough service plate and screw back the cable blockage. Screw the backplate in place. UV222 Industrial Technical & Installation Manual...
  • Page 11: Understanding The Unit's Operation

    22.0 mJ/cm² for an 8 h day, 40 h work week exposure to UV radiation at 222 nm. (UV Medico A/S expects positive changes into the ACGIH that will result in a higher expo- sure than allowed at this moment. If this changes, UV Medico A/S will update the software of the unit to align with the new threshold of exposure).
  • Page 12 If the Product was already installed, you can recover its settings by pressing “Get”. All settings will then be shown in the application. Check if firmware version is the latest. If not, press “Update FW”. UV222 Industrial Technical & Installation Manual...
  • Page 13 Select the correct firmware version and press “Open” to upload. When the app asks to confirm, click on "Yes". When finished installing, the firmware should be up to date. Set the correct hour by pressing “Set Time and Zone”. The date and hour are now the same as your computer. Define the timing of the use (duty cycle) of the room where the Product is installed: “On time”: Time from which the room will be occupied by people.
  • Page 14 Change the intensity of the LED signal to the desired output. Select mode. NOTE: The current model does not have either motion or distance sensor. Therefore, only valid mode is Normal, where the Product will follow the settings as provided. UV222 Industrial Technical & Installation Manual...
  • Page 15 Save setup into template by pressing “Save Setup”. Name the template. This can be recalled whenever you have similar settings. 10) Press “Set” to upload the settings into the Product. Once this information is saved and programmed into the unit, it is ready to test/start up. The unit will calculate the radiation automatically to stay within the limits of the ACGIH like the example below: Occupied timeslot...
  • Page 16 10 sec. after the security distance is cleared. If the information programmed into the Product when installed is different than the use/ occupancy of the room, UV Medico A/S cannot be held liable for any injuries or misuse of these units.
  • Page 17: Understanding The Function Of The Signal Led

    Pre disinfection / after disinfection per seen movement. Red-blue-green (loop) Recommended change of Far UV-C light source. If the LED is red, contact your local UV Medico distributor. 6.8. Replacements The Product has an internal battery that can be replaced if broken or empty.
  • Page 18: Product Failure

    White flash Power cycle the unit. Does not hold settings Replace battery. If the failure is unsolved or recurring, please return the unit to an official UV Medico dealer/ REPAIRS). service centre for repair or replacement (see point CLEANING AND MAINTENANCE Clean the external surfaces with a soft cloth and non-aggressive cleaning agents only.
  • Page 19: Light Source Replacement

    2-year warranty is given from invoice date regardless on the hours the unit is used. UV222™ and its logo are registered trademarks of UV Medico A/S. All rights reserved. No part of this manual may be copied or published by means of printing, photocopying, microfilm or otherwise without the prior written consent of the manufacturer.
  • Page 20 UV Medico A/S Søren Frichs Vej 40E 8230 Åbyhøj Denmark +45 20 90 71 30 info@uvmedico.com www.uvmedico.com...