Start-up
Please observe the hazard information in section see „2 Hazard infor-
mation" on page 28 during installation.
A minimum load of 1 W is required for operating in two-way or cross
circuits.
Permitted cable cross sections for connecting to the device are:
Rigid cable [mm
0.75 – 2.50
6.2
Installation overview
Homematic IP
Switch Module for
brand switches
6.3
Installation
To remove an existing switch, follow the instructions of the respec-
tive switch manufacturer.
You can use the Switch Module in the following circuits:
•
On-off circuit (see figure 3)
•
Two-way circuit (see figure 4)
•
Intermediate switch circuit (see figure 5)
To install the Switch Module, proceed as follows:
•
Switch off the circuit breaker for the power circuit (see figure 2).
34
]
flexible cable with/without ferrule [mm
2
0.75 – 2.50
Suitable
adapter
Frame
(example)
]
2
Rocker
(example)