Technical Specification - welldana 34-180139 Installation And User Manual

Hide thumbs Also See for 34-180139:
Table of Contents

Advertisement

3. Technical specification

Model
Advised pool volume (m
Working air temp (℃)
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
Heating capacity (kW) in silence
mode
C.O.P
C.O.P in silence mode
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
Heating capacity (kW) in silence
mode
C.O.P
C.O.P in silence mode
Rated input power (kW)
Rated input current (A)
Power supply
Advised water flux
Sound pressure 1m dB(A)
Sound pressure 10m dB(A)
Water pipe in-out Spec (mm)
Net Dimension LxWxH (mm)
Net Weight
1. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration
system running at least 15 hours a day
2. Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
3
)
(m³/h)
(kg)
34-180139
25-50
-7~43
11.3~2.8
9.0~2.8
15.1~6.5
15.1~7.5
7.3~1.9
5.8~1.9
7.7~4.5
7.7~5.2
1.6~0.22
7.4~0.95
230V/1 Ph/50Hz
4~6
39.5~48.2
19.5~28.2
50
961×312×658
50
- 6 -
For users
34-180140
30-60
13.3~3.4
10.4~3.4
15.0~6.4
15.0~7.4
9.4~2.3
7.4~2.3
7.6~4.4
7.6~5.1
2.1~0.25
9.1~1.1
5~7
42.8~52.1
22.8~32.1
961×312×658
52

Advertisement

Table of Contents
loading

This manual is also suitable for:

34-180140

Table of Contents