1. Wiring diagram
For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
Note: For your safe use in winter, it's strongly recommended to equip heating priority
function. For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
Breaker
Power Cord(mm
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m .If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
MODEL
Rated Current A
Rated Residual
Action Current mA
Fuse
A
2
2
For installers and professionals
Swimming Pool Heat Pump Wiring Board
Power Cord
34-180139
12
30
12
3×2.5
3×0.5
- 10 -
34-180140
13
30
13
3×2.5
3×0.5