Size(mm)
Model
34-180139
34-180140
Above data is subject to modification without notice.
① The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
2.2.2. Heat pump installation.
concrete foundation must be solid; the bracket must be strong enough and anti-rust
② The heat pump needs a water pump (Supplied by the user). The recommended pump
treated;
③ When the heat pump is running, there will be condensation water discharged from the
specification-flux: refer to Technical Parameter, Max. lift ≥10m
bottom, please pay attention to it. Please insert the drainage tube(accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
① Connect to appropriate power supply, the voltage should comply with the rated voltage
2.2.3. Wiring & protecting devices and cable specification
② Well earth the heat pump.
of the products.
③ Wiring must be connected by a professional technician according to the circuit
④ Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
diagram.
⑤ The layout of power cable and signal cable should be orderly and not affecting each
other.
A
B
C
D
315 590 312 340
315 590 312 340
- 9 -
For installers and professionals
E
F
G
961
340
74
961
340
74
H
658
658

Advertisement