Utilitech 7105-08-L Manual page 4

3-in-1 decorative ventilation fan with led light
Table of Contents

Advertisement

Available languages

Available languages

PREPARATION (Continued)
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
Installation may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all
included; however, most are available at your local home improvement or hardware store.
DIMENSIONS
Ceiling
Opening (L)
Opening (W)
7-3/4 in.
WIRING
All wiring must be connected for full functionality. Do not use metal wall plate with switch.
FAN
BATH FAN
TYPICAL INSTALLATION
It is recommended to apply proper insulation around the fan to
minimize heat loss and gain. This fan is designed to be installed
using a 4-in. duct.
Using a rigid duct is recommended. Using a flexible duct, cut to
size and/or fully extended is also acceptable. Ducting has a strong
effect on the air flow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for best performance.
Avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit
mold growth. Fans installed with existing ducts may not achieve
their rated air flow.
Ceiling
Ceiling
Opening (H)
7-1/2 in.
6 in.
Single Switch
Switch Box
Black LED
& Fan
White LED
& Fan
Green
Two Switch
Housing
Dimension (L)
7-1/2 in.
Live
Neutral
Ground
• Strip wires 3/8 in. - 1/2 in.
• Grip the wire firmly and push the stripped end of the
wire into the open port of the connector. Use only one
conductor per port.
• Verify the stripped end of the wires is fully inserted to
the back of the connector.
Properly insulate
around fan to
minimize building
heat loss and gain
Fan housing
Seal any gap
around fan
housing
4
Housing
Dimension (W)
7-1/4 in.
WARNING: Wiring must comply with all
applicable electrical codes. Turn off power
before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY.
Do not use aluminum wire.
CAUTION: Accessory part (quick connector)
should meet installation instructions below.
Quick
connect
House
wires
NOTE: The connector is reusable on solid
wires of the same wire gauge or smaller. Do
not reuse the connector on stranded wires.
CAUTION: Wiring maximum temperature rating
221˚F (105˚C). 600V maximum for building wiring
and 1,000V maximum for signs and light fixtures.
The acceptable wire range is 12-18 AWG Sol. Cu.
Short piece of
flexible duct helps
alignment and
absorbs sound
2-3 foot straight
run before
elbow
Housing
Dimension (H)
5-3/4 in.
Product
wires
Roof cap
(with built-in
damper)
Caulk
termination
to duct
Wall cap
(with
built-in
damper)