Troubleshooting; Malfunctions When Starting; Table 23: Malfunctions When Starting - Delayed Start-Up; Table 24: Malfunctions When Starting - Vibrations - ABB PT004162 Operation Manual

Table of Contents

Advertisement

Operation Manual / Power2 845-M / High-pressure stage
8 Troubleshooting / 8.1 Malfunctions when starting
8

Troubleshooting

8.1

Malfunctions when starting

Delayed start-up
Possible causes
Low-pressure
Pressure stage contaminated
or
Bearing damaged
high-pressure
Rotor rubbing
stage
Foreign object in pressure stage
Table 23: Malfunctions when starting – Delayed start-up
Vibrations
Possible causes
Engine
Vibrations from engine
Low-pressure
Rotor unbalance
or
Turbine or compressor damaged
high-pressure
Bearing damaged
stage
Table 24: Malfunctions when starting – Vibrations
Rubbing of rotating parts
Normal behaviour, not a malfunction
Low-pressure
A minimal and uniform wear at the circumference of the rotor components
or
caused by slight local rubbing against adjacent components is permitted. This
high-pressure
causes the compressor or turbine blades to be somewhat shortened. To pre-
stage
vent significant loss of efficiency, specific tolerances must be fulfilled.
¡
If there is any doubt about the extent of the rubbing, contact a Turbo
Systems service station.
¡
Have a dimension check carried out by a Turbo Systems service station.
Table 25: Malfunctions when starting – Rubbing of rotating parts
© Copyright 2022 ABB. All rights reserved.
Remedy
Clean
Contact a Turbo Systems service sta-
tion
Remedy
Contact enginebuilder
Contact a Turbo Systems service sta-
tion
HZTL4069_EN
Rev.F
March 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power2 845-m46

Table of Contents