COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
TCHE48S4(3,4)S1
CP9C120D20MP13C
TCHE48S4(3,4)S1
CPLC080C16MP12C
TCHE48S4(3,4)S1
CPLC080C16MP13C
TCHE48S4(3,4)S1
CPLC100C16MP12C
TCHE48S4(3,4)S1
CPLC100C16MP13C
TCHE48S4(3,4)S1
CPLC100C20MP12C
TCHE48S4(3,4)S1
CPLC100C20MP13C
TCHE48S4(3,4)S1
CPLC120C20MP12C
TCHE48S4(3,4)S1
CPLC120C20MP13C
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. High Efficiency Motor Furnaces have B.O.D (Blower Off Delay) standard.
2. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

APPLICATIONS AND ACCESSORIES

Refer to Price Manual for specific model numbers.
Standard Application Limits*
Maximum Lineset Equivalent Length
Outdoor Ambient Temperature Limits
Cooling Operation
*
For Low Ambient and/or Long Lineset Applications, please see the acces-
sories listed below.
Non-Standard Lineset Applications - For installations with
reduced diameter or long linesets, refer to the current version of
the Piping Application Guide P/N 247077, available in the Appli-
cation Bulletins section on www.simplygettingthejobdone.com.
OD Unit Anti Short Cycle Kit (10 Pack) S1-2TD08700124BK:
A time delay that prevents rapid compressor restarting as a
result of power interruption, limit switch operation, or thermostat
resetting. Not required for HP models, or for AC models with
factory electronic controls.
Standard Low Ambient Control Kit S1-2LA06700424: Allows
the use of air conditioning at low outdoor ambient temperatures
down to +20°F (-7°C). For use with all R-410A single stage AC
& HP models.
Advanced Low Ambient Control Kit S1-2LA04701024: Con-
tains the necessary components and controls to allow cooling
operation down to -20ºF (-29ºC). For use with some R-410A
single stage AC & HP models. This accessory can only be
applied to models that contain a PSC outdoor fan motor.
Low Pressure Switch Kit S1-2PS06700524: Provides field
installed low pressure (loss of charge) protection. Not required
for HP models, or for AC models with factory electronic con-
trols.
High Ambient Outdoor Fan Motor S1-FHM****HT: Class F
70°C motor to allow cooling operation up to 160ºF air entering
the outdoor coil. For use with all R-410A single stage AC & HP
models containing R-410A refrigerant only.

SOUND POWER RATINGS

Cooling
Model Number
TCHE36S4(3,4)S11
TCHE48S4(3,4)S11
Rated in accordance with ARI Standard 270.
8
FURNACE
MODEL
WIDTH
24.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
Maximum DB
Minimum DB
63
125
250
74
77
75
81
1
(Continued)
COIL
RATED
2
MODEL
CFM
FC49D
1200
FC49D
1425
FC49D
1200
FC49D
1425
FC49D
1200
FC49D
1425
FC49D
1225
FC49D
1425
FC49D
1225
Outdoor Communicating Board Kit (S1-33102952310): Elec-
tronic control upgrade for standard AC units to provide compati-
bility with the Residential Touch Screen Communicating
200 Ft
Control.
Compressor Crankcase Heater Kit (S1-025-*****-***): A
120°F
wrap-around electrical resistance heater that warms the com-
pressor sump, reducing the chance of liquid slugging on
50°F
startup. Required on all long lineset and low ambient applica-
tions. See Price Pages or Source1 SmartSearch for the correct
part for each application.
Indoor TXV Kit S1-1TVM***: Thermal expansion valves pre-
cisely meter refrigerant for optimum performance over a wide
range of conditions. See System Charge Table, Price Pages, or
Source1 Smart Search for TXV part number for each AC & HP
model.
Cold Weather Charging Tent S1-CHGTENT01: Provides
warm environment to accurately service AC & HP systems in
ambient conditions 55ºF (13ºC) or colder.
Touch-up Paint S1-5130153****: Color matched aerosol paint
for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.
Compressor
installed dense foam cover that provides 2dBA sound level
reduction. See Price Pages or Source1 SmartSearch for the
correct blanket for each application.
Thermostat: Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our Coleman Hx™
Touchscreen Thermostats available through Source1. For more
information, see the thermostat section of the Product Equip-
ment Catalog.
Octave Band Sound Power Level (db re. 1-pW)
500
1000
68
67
66
70
68
66
COOLING
NET MBH
TOTAL
SENS.
45.5
32.0
46.0
34.4
45.5
32.2
46.0
34.4
45.5
32.2
46.0
34.2
45.5
32.4
46.0
34.2
45.5
32.4
Sound
Blanket
S1-0100764*000: A field
2000
4000
61
58
61
58
Johnson Controls Ducted Systems
SEER
EER
15.10
12.50
14.25
12.00
14.75
12.25
14.25
12.00
14.75
12.25
15.00
12.50
15.00
12.50
15.00
12.50
15.00
12.50
8000
dBA
58
71
58
72