Coleman ECHELON AC21 Series Technical Manual

Coleman ECHELON AC21 Series Technical Manual

Split system air conditioners

Advertisement

Quick Links

TECHNICAL GUIDE
TM
ECHELON
SERIES
SPLIT SYSTEM
AIR CONDITIONERS
20 SEER – R-410A – 1 PHASE
2 THRU 5 NOMINAL TONS
MODELS: AC21B24 THRU 60
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.simplygettingthejobdone.com and
www.colemanac.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Extended 10-Years limited parts warranty.
Extended Lifetime limited compressor warranty.
Extended parts and compressor warranties require online
registration within 90 days of purchase for replacement or
closing for new home construction.
*Does not apply to 3-Phase models, or Internet sales.
See Limited Warranty certificate in User's Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
FOR INSTALLATION IN ALL US REGIONS AND CANADA
Installation Allowed

DESCRIPTION

The Echelon™ Series AC21 variable capacity air conditioners
are the outdoor section of a high efficiency communicating cool-
ing system. They are designed as part of a matched system
using an AVV air handler or variable speed communicating fur-
nace with a CM coil. Both the matched CM coil and AVV air
handler have factory mounted EEVs. The CM coils with factory
mounted EEVs can also be matched with the variable speed
MVC modular air handlers.

FEATURES

• Superior Coil Protection – An easily removable two-piece
steel extruded louver coil guard protects the tube-in-fin coil
from debris and physical damage while making access for
coil cleaning quick and simple.
• Environmentally Friendly Refrigerant – The next genera-
tion refrigerant R-410A delivers environmentally friendly per-
formance with zero ozone depletion.
• Durable Finish – A high quality powder paint finish rated at
1000 hrs. salt spray provides the ultimate protection from
corrosion and harmful UV rays, ensuring a long-lasting, high
quality appearance.
• Charge View™ – A built-in touch screen instantly displays
the system overall condition, including the system pressures
and refrigerant charge without the need to attach additional
gauges or sensors.
• WhisperDrive™ System – Features a combination of engi-
neered, sound-neutralizing attributes such as a swept-wing
fan blade, composite base pan, multi-density compressor
cloak and variable capacity operation to reduce sound levels
to that of a mere conversation.
• ECM Fan Motor – Dynamically adjusts speed in sync with
the compressor demand to keep heat exchange in balance
while minimizing power consumption and sound.
• Swept Wing Fan – A design adapted from aerospace engi-
neering provides whisper-quiet operation by allowing air to
flow smoothly and efficiently across the fan surface and
edges.
• Composite Base Pan – The strong and durable composite
base pan is corrosion resistant while adding strength,
absorbing sound, and reducing vibration.
• High-Efficiency Outdoor Coil – An aluminum fin and cop-
per tube outdoor coil provide easy cleaning, low restriction to
airflow and efficient heat exchange.
• Factory Installed Filter Drier – The liquid line filter drier
removes debris and moisture which can be harmful to the
system.
• Climate Connect™ – provides pre-configured operating
profiles the installing contractor can select during set-up to
fine tune the system's operation for either Humid, Dry, or
Normal climates. Additional fine-tune adjustments are
always available to provide a custom comfort solution.
• Easy Service Access – A large electrical box cover, inde-
pendent Charge View access, and a swing open electrical
box provide superior full corner access to the inside of the
unit for maintenance or service.
• System Protection – Each system contains high and low
pressure transducers which constantly monitor system per-
formance and can alert the consumer or contractor system
concerns or alerts.
• EEV Controls – All indoor coils, whether in the cased CM
coil or in the AVV air handler, have factory installed EEVs
(Electronic Expansion Valves).
5443702-CTG-C-0919

Advertisement

Table of Contents
loading

Summary of Contents for Coleman ECHELON AC21 Series

  • Page 1: Description

    5443702-CTG-C-0919 DESCRIPTION The Echelon™ Series AC21 variable capacity air conditioners are the outdoor section of a high efficiency communicating cool- ing system. They are designed as part of a matched system using an AVV air handler or variable speed communicating fur- nace with a CM coil.
  • Page 2: Table Of Contents

    A = Premium Air Conditioner PRODUCT TYPE cating system provides self-commissioning on start-up as well as the ability to check system status at the outdoor unit, C = Coleman BRAND thermostat, or remotely using the designated App. NOMINAL • Variable Capacity Inverter Controlled Scroll Compressor...
  • Page 3: Physical And Electrical Data

    5443702-CTG-C-0919 PHYSICAL AND ELECTRICAL DATA MODEL AC21B2421S AC21B3621S AC21B4821S AC21B6021S Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 17.4 25.7 28.6 33.9 Max. Overcurrent Device Amps Type Scroll Scroll Scroll Scroll Compressor Rated Load 12.8 19.2 20.8...
  • Page 4: System Charge For Various Matched Systems

    5443702-CTG-C-0919 SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit AC21B2421S AC21B3621S AC21B4821S AC21B6021S Additional Charge, oz Indoor Unit AVV25BE121 – – – AVV37BE221 – – – AVV37CE221 – – – AVV49CE321 – – – AVV49DE321 – – – AVV61CE421 – –...
  • Page 5: Limitations

    5443702-CTG-C-0919 LIMITATIONS Unit Reduced Capacity Conditions The unit should be installed in accordance with all National, State and NOTICE Local Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessories Inverter Temperature Protection: must also be observed.
  • Page 6: System Capacity - Single Piece And Modular Air Handlers

    5443702-CTG-C-0919 SYSTEM CAPACITY - Single Piece and Modular Air Handlers AIR HANDLER COOLING UNIT COIL RATED Stage NET MBH MODEL MODEL MODEL WIDTH SEER TOTAL SENS. High 23.40 17.70 21.00 14.50 AC21B2421S AVV25BE121 17.5 – 14.10 11.20 – 18.50 10.00 7.90 –...
  • Page 7: Cooling Capacity - With High Efficiency Motor Furnaces

    5443702-CTG-C-0919 COOLING CAPACITY - With High Efficiency Motor Furnaces FURNACE COOLING UNIT COIL STAGE NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. High 23.4 18.3 20.75 14.50 AC21B2421S TM8V080B12MP12C 17.5 CM25BE1A1 14.0 11.5 – 19.35 – 37.20 High 23.0 17.4 20.50...
  • Page 8 5443702-CTG-C-0919 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL STAGE NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. High 1200 34.8 26.2 19.25 13.00 AC21B3621S TMLV080C16MP12C 21.0 CM37CE2A1 18.9 15.6 – 18.60 10.8 –...
  • Page 9 5443702-CTG-C-0919 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL STAGE NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. High 1525 45.5 33.2 19.50 12.50 AC21B4821S TM8V120C20MP12C 21.0 CM49CE3A1 25.0 20.0 – 18.65 14.4 11.1 –...
  • Page 10 5443702-CTG-C-0919 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL STAGE NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. High 1500 45.5 32.8 19.50 12.25 AC21B4821S CP9C080C16MP13C 21.0 CM49CE3A1 25.0 19.1 – 18.80 14.6 12.8 –...
  • Page 11: Accessories

    Thermostat: These advanced, communicating, variable capac- Wall Mount Kit (S1-ACB-**): Includes two brackets to allow ity designs require the Coleman Hx™ Touchscreen Thermo- outdoor unit to be securely mounted to a vertical wall. Mounting stats available through Source1. For more information, see the hardware is field sourced according to the specific application.
  • Page 12: Unit Operation

    5443702-CTG-C-0919 UNIT OPERATION UNIT CONSTRUCTION • Units shall be shipped completely wired, piped and assem- COOLING OPERATION bled. Wiring pigtails shall be provided for field control wiring During cooling operation, the main outdoor control will receive a connections. Service valves shall be provided for field refrig- communicated demand signal along with the current space erant line connections.
  • Page 13: Typical Installation

    5443702-CTG-C-0919 TYPICAL INSTALLATION CAUTION Care must be taken to prevent ice from damaging the unit. Damage may occur from ice falling onto unit from a sloped roof or from a vertical drip line due to a partial overhang. Johnson Controls Ducted Systems...
  • Page 14: Typical Field Wiring

    5443702-CTG-C-0919 TYPICAL FIELD WIRING ALTERNATIVE INSTALLATION CLEARANCES Johnson Controls Ducted Systems...
  • Page 15: Performance Data - 2 Ton

    5443702-CTG-C-0919 PERFORMANCE DATA - 2 TON NOTICE Outdoor units must be applied with Johnson Controls Unitary Products indoor coils, so Condenser Only data is not provided. COOLING PERFORMANCE DATA- HIGH AIR CONDITIONER MODEL NO. AC21B2421S IDCFM AIR TEMP. ENTERING ID DB (°F) OUTDOOR UNIT (°F) ID WB (°F) T.C.
  • Page 16: Performance Data - 3 Ton

    5443702-CTG-C-0919 PERFORMANCE DATA - 3 TON NOTICE Outdoor units must be applied with Johnson Controls Unitary Products indoor coils, so Condenser Only data is not provided. COOLING PERFORMANCE DATA - HIGH AIR CONDITIONER MODEL NO. AC21B3621S IDCFM 1020 1200 1320 AIR TEMP.
  • Page 17: Performance Data - 4 Ton

    5443702-CTG-C-0919 PERFORMANCE DATA - 4 TON NOTICE Outdoor units must be applied with Johnson Controls Unitary Products indoor coils, so Condenser Only data is not provided. COOLING PERFORMANCE DATA - HIGH AIR CONDITIONER MODEL NO. AC21B4821S IDCFM 1360 1560 1760 AIR TEMP.
  • Page 18: Performance Data - 5 Ton

    PERFORMANCE DATA - 5 TON NOTICE Outdoor units must be applied with Johnson Controls Unitary Products indoor coils, so Condenser Only data is not provided. COOLING PERFORMANCE DATA - HIGH AIR CONDITIONER MODEL NO. AC21B6021S IDCFM 1530 1800 1980 AIR TEMP. ENTERING ID DB (°F) OUTDOOR UNIT (°F)

Table of Contents