COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
MODEL
AC19B6021S
CPLC120C20MP13C
AC19B6021S
CPLC120C20MP13C
AC19B6021S
CPLC120C20MP13C
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. High Efficiency Motor Furnaces have B.O.D (Blower Off Delay) standard.
2. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

APPLICATIONS AND ACCESSORIES

Refer to Price Manual for specific model numbers.
Standard Application Limits*
Maximum Lineset Equivalent Length
Outdoor Ambient Temperature Limits
Cooling Operation
*
For Low Ambient and/or Long Lineset Applications, please see the acces-
sories listed below.
Non-Standard Lineset Applications - For installations with
reduced diameter or long linesets, refer to the current version of
the Piping Application Guide P/N 247077, available in the Appli-
cation Bulletins section on www.simplygettingthejobdone.com.
Start Assist Kit S1-2SA067*****: Provides increased compres-
sor starting torque for areas with low supply voltage. Required
for all units when applied with long linesets. See Price Pages or
Source1 SmartSearch for the correct kit for each application.
Compressor Crankcase Heater Kit (S1-325-*****-***): A
wrap-around electrical resistance heater that warms the com-
pressor sump, reducing the chance of liquid slugging on
startup. Required on all long lineset applications. See Price
Pages or Source1 SmartSearch for the correct part for each
application.
Support Feet S1-HPRKIT-**: Kit of 5 support feet to raise unit
above snow or landscaping. Available in heights of 3", 6" or 12".
Anchor Bracket Ground Mount Kit S1-1HK0701: Firmly
anchors unit to pad or support structure. When properly
installed, approved for ground-mounted applications.

SOUND POWER RATINGS

Stage 1 Cooling
Model Number
AC19B2421S
AC19B3621S
AC19B4821S
AC19B6021S
Stage 2 Cooling
Model Number
AC19B2421S
AC19B3621S
AC19B4821S
AC19B6021S
Rated in accordance with ARI Standard 270.
Johnson Controls Ducted Systems
FURNACE
WIDTH
21.0
21.0
21.0
Maximum DB
Minimum DB
63
125
250
66
67
62
66
67
70
68
69
71
71
70
75
63
125
250
64
66
67
66
69
72
74
72
69
68
71
73
1
(Continued)
COIL
STAGE
2
MODEL
1
CF/CM/CU60C
2
1
CF/CM/CU60D
2
1
CF/CM64D
2
Anchor Bracket Roof Mount Kit S1-1HK0901: Firmly anchors
unit to pad or support structure. When properly installed,
approved for roof-mounted applications.
Indoor TXV Kit S1-1TVM***: Thermal expansion valves pre-
80 Ft
cisely meter refrigerant for optimum performance over a wide
range of conditions. See System Charge Table & Price Pages
for TXV part number for each AC & HP model.
125°F
Wall Mount Kit (S1-ACB-**): Includes two brackets to allow
35°F
outdoor unit to be securely mounted to a vertical wall. Mounting
hardware is field sourced according to the specific application.
Winter Cover Kit S1-CCVRE***: Custom fit winter cover pro-
tects AC condensing unit from debris during the off-season.
Must be removed prior to unit operation. See Price Pages for
the correct cover for each application.
Cold Weather Charging Tent S1-CHGTENT01: Provides
warm environment to accurately service AC & HP systems in
ambient conditions 55ºF (13ºC) or colder.
Touch-up Paint S1-5130153****: Color matched aerosol paint
for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.
Thermostat: Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our Coleman Hx™
Touchscreen Thermostats available through Source1. For more
information, see the thermostat section of the Product Equip-
ment Catalog.
Octave Band Sound Power Level (db re. 1-pW)
500
1000
2000
65
66
68
65
71
69
73
69
Octave Band Sound Power Level (db re. 1-pW)
500
1000
2000
64
65
71
71
69
72
72
69
COOLING
NET MBH
RATED
CFM
TOTAL
SENS.
1075
45.5
31.6
1550
57.5
41.5
1100
46.0
31.8
1625
58.0
42.5
1050
45.5
31.2
1550
58.5
42.0
4000
8000
59
52
47
59
57
55
61
55
53
63
58
56
4000
8000
56
51
49
59
55
54
62
55
54
62
57
53
5493752-CTG-F-0420
SEER
EER
22.60
16.00
12.50
22.85
16.25
12.50
22.90
16.25
12.75
dBA
SQI
68
19.0
69
19.1
72
19.1
74
19.2
dBA
SQI
67
19.0
73
19.1
73
19.1
74
19.2
57