System Configuration (parameters)

General

508.0 "UTC time zone"
Setting
2
–24 to +24
896.0 "Display correction for outside temperature"
Setting
0
-10 to + 10
912.0 "Automatic summer/wintertime changeover"
Setting
No
0
Yes
1
912.1 "Earliest day of changeover from winter to summertime"
Setting
25
1 to 31
912.2 "Month of changeover from winter to summertime"
Setting
3
1 to 12
912.3 "Earliest day of changeover from summer to wintertime"
Setting
25
1 to 31
912.4 "Month of changeover from summer to wintertime"
Setting
10
1 to 12
1098.4 "Gas volume correction factor"
Setting
1,0000
.7000 to 1.0000
62
Explanations
Setting of the UTC time zone in which the boiler is located.
The factory setting is UTC +1 h
Time difference adjustable from –12 h to +12 h in increments of 0.5 h
Explanations
Correction of measured outside temperature
Correction in the factory setting 0 K (0°F)
Correction adjustable from -10 to + 10 K in 1 K increments
(-18°F to +10°F in 1.8°F increments)
Explanations
Automatic changeover switched off
Automatic changeover switched on
Explanations
Changeover from 02:00 h to 03:00 h occurs on the Sunday after or on this set date.
Day of changeover adjustable from 1st to 31st of the month
Explanations
Month of changeover: March
Month of changeover adjustable from January to December
Explanations
Changeover from 03:00 h to 02:00 h occurs on the Sunday after or on this set date.
Day of changeover adjustable from 1st to 31st of the month
Explanations
Month of changeover: October
Month of changeover adjustable from January to December
Explanations
Value is provided on the gas supplier's bill. Used for gas consumption data.
Calorific value adjustable from 0.7000 to 1.0000 in increments of 0.0001.
Vitodens 100-W, B1HE/B1KE Combi Installation/Service
Note: Parameter values in bold are factory settings.