Calibrate The Scanner (Wand Scan Mode) - Pandigital PANSCN10 User Manual

Portable wand scanner with feeder dock
Table of Contents

Advertisement

Use only the recommended and supplied tools to clean the scanner and feeder dock.
WARNING: Do not use any solvents or corrosive liquid (i.e., alcohol, kerosene, etc.) to clean
1. Use a suitable dust blower to blow off dust from the scanner and feeder dock.
2. Use a slightly dampened cloth to wipe off any smear on the surface of the scanner and LCD
screen.
3. Gently wipe the feed rollers on the scanner and feeder dock, and the CIS cover with the
cleaning cloth (included).
4. Wipe the scanner and feeder dock with a dry and clean lint-free cloth.
C al i b r at e  the  Scanner (Wa n d Sc an m o de ) 
AS NEEDED ONLY!
darker than normal) after 8K+ scans or the scanner has been stored without use for a long time.
The calibration process resets the Contact Image Sensor to resume its color & sharpness
precision.
 Calibration can only be performed with the wand scanner out of the feeder dock. When the
scanner is engaged in the feeder dock, the calibration feature is disabled.
 If there are lines on the scanned images, use a clean cloth to gently wipe the CIS cover.
Complete the following steps to calibrate your scanner:
1. Make sure the battery is fully charged and a memory card is inserted.
2. Remove the calibration sheet from its plastic cover and lay it on a flat surface, printed side up.
3. Remove the scanner from the feeder dock.
 The calibration can only be performed using the scanner as a wand scanner.
4. Place the scanner on the calibration sheet, at the top of the white area.
 Make sure the sheet is clean (i.e., no debris or colored objects).
5. With the
6. Press
7. Press
8. Press
9. Scanner enters Calibration mode. Slowly slide the scanner down over ONLY the white
area of the calibration sheet.
10. The scanner completes the calibration sequence and automatically powers off.
11. Carefully place the calibration sheet back into the plastic cover and store until next use.
WARNING: Do not interrupt the calibration sequence or try to shut off the device while
any part of the scanner or feeder dock, otherwise the plastic material may be
permanently damaged.
Calibrate only if the scanned image looks fuzzy or the color is off (e.g.,
screen displayed, press
Settings
to select
Calibration
to scroll to
Yes
to select
.
it is calibrating. If you stop the calibration before it has completed, a
calibration error may occur. As a result, when you next power up the unit,
an error message may be displayed, and you will have to power off the unit
and repeat the instructions in this section.
to enter Menu mode.
.
, and then press
to select it.
35

Advertisement

Table of Contents
loading

Table of Contents