System Capacity - With Air Handler Coils - Coleman ECHELON Series Technical Manual

Split system air conditioners
Table of Contents

Advertisement

With Air Handler Coils
SYSTEM CAPACITY -
UNIT
MODEL
MODEL
AC19B2421S
AE24BX21
AC19B2421S
AE30BX21
AC19B2421S
AE36CX21
AC19B2421S
AVC24BX21
AC19B2421S
AVC30BX21
AC19B2421S
AVC36BX21
AC19B2421S
AVC36CX21
AC19B2421S
AVC42CX21
AC19B2421S
AVC48CX21
AC19B2421S
AVC48DX21
AC19B2421S
ME08BN21
AC19B2421S
ME08BN21
AC19B2421S
ME08BN21
AC19B2421S
ME08BN21
AC19B2421S
ME12BN21
AC19B2421S
ME12BN21
AC19B2421S
ME12BN21
AC19B2421S
ME12BN21
AC19B2421S
ME12CN21
AC19B2421S
MVC08BN21
AC19B2421S
MVC08BN21
AC19B2421S
MVC08BN21
AC19B2421S
MVC08BN21
AC19B2421S
MVC12BN21
AC19B2421S
MVC12BN21
AC19B2421S
MVC12BN21
Johnson Controls Ducted Systems
AIR HANDLER
WIDTH
17.5
17.5
21.0
17.5
17.5
17.5
21.0
21.0
21.0
24.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
21.0
17.5
17.5
17.5
17.5
17.5
17.5
17.5
COIL
RATED
STAGE
1
MODEL
CFM
1
675
2
850
1
625
2
750
1
725
2
875
1
550
2
850
1
625
2
875
1
650
2
925
1
625
2
900
1
625
2
900
1
600
2
925
1
550
2
875
1
625
CF/CM24B
2
800
1
625
CF/CM30B
2
900
1
625
CF/CM36B
2
900
1
625
CF42B
2
900
1
700
CF/CM24B
2
875
1
700
CF/CM30B
2
875
1
700
CF/CM36B
2
875
1
700
CF42B
2
850
1
650
CF/CM24C
2
850
1
525
CF/CM24B
2
800
1
525
CF/CM30B
2
800
1
525
CF/CM36B
2
800
1
525
CF42B
2
825
1
625
CF/CM24B
2
875
1
625
CF/CM30B
2
875
1
625
CF/CM36B
2
875
5493752-CTG-F-0420
COOLING
NET MBH
SEER
TOTAL
SENS.
20.20
16.20
17.75
23.40
19.20
20.20
15.50
18.50
23.60
18.20
21.00
16.90
19.25
23.80
19.30
19.60
14.50
18.00
23.20
19.00
20.20
15.50
18.50
23.60
19.20
20.40
16.20
18.75
23.80
19.90
20.40
15.60
18.75
23.80
19.80
20.40
15.80
19.25
23.80
19.60
20.40
15.60
19.25
23.80
19.90
20.00
14.60
19.25
23.80
19.20
19.90
15.50
18.00
23.20
18.40
20.20
15.50
18.50
23.60
19.30
20.40
15.60
18.50
23.80
19.70
20.40
15.60
19.00
23.80
19.60
20.40
16.50
18.00
23.40
19.50
20.60
16.60
18.50
23.60
19.20
20.60
16.80
18.75
23.80
19.30
20.80
16.70
19.00
23.80
19.30
20.20
15.90
18.25
23.40
19.20
19.40
14.10
17.75
23.20
18.40
19.60
14.20
18.25
23.60
18.50
19.60
14.30
18.50
23.80
18.70
19.80
14.20
18.75
23.80
19.00
20.00
15.50
18.00
23.40
19.50
20.20
15.50
18.50
23.60
19.20
20.40
15.60
18.75
23.80
19.30
EER
26.80
14.75
27.25
15.00
28.80
15.50
26.95
14.50
27.35
14.75
27.65
15.00
28.10
15.25
28.35
15.50
28.20
15.50
27.95
15.50
26.85
14.75
27.50
14.75
27.80
15.00
27.95
15.00
27.15
14.75
27.55
15.00
27.70
15.25
28.05
15.25
27.35
15.00
26.80
14.75
27.00
15.00
27.15
15.00
27.55
15.00
27.15
14.75
27.65
15.00
27.95
15.25
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac19b2421sAc19b3621sAc19b4821sAc19b6021s

Table of Contents