Siemens SIMATIC HMI Industrial Thin Client ITC1200 Operating Instructions Manual page 114

Hmi device
Table of Contents

Advertisement

Technical specifications
9.4 Technical specifications
Testing mechanical ambient conditions
The following table provides information on the type and scope of tests for mechanical
ambient conditions.
Tested for
Vibrations
Shock
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Temperature:
Vertical mounting
Mounting at an angle
Relative humidity
Atmospheric pressure
Pollutant concentration
1
114
Test standard
Vibration test in accordance
with IEC 60068, part 2–6
(sinusoidal)
Shock test in accordance
with IEC 60068, Part 2 –27
ITC1900 and ITC2200: From 0 to 45° C
Comments
Type of vibration:
Frequency cycles at a rate of change of 1
octave/minute.
5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 0.075 mm
8.4 Hz ≤ f ≤ 150 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three
mutually vertical axes
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the
three axes vertical to each other
Permitted range
From 0 to 50 °C (horizontal)
From 0 to 40 °C (horizontal)
10 to 90%, without condensation
1 080 to 795 hPa
SO
: < 0.5 vpm;
2
Relative humidity < 60%, no
condensation
H
S: < 0.1 vpm;
2
Relative humidity < 60%, no
condensation
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Comments
1
Slope angle max. 35°
Corresponds to an elevation
of -1000 m to 2000 m
Test: 10 cm
Test: 1 cm
/m
3
Operating Instructions, 04/2013, A5E03474888-02
1
/m
; 10 days
3
3
; 10 days