Unlock Led Indicator Command; Time Correction - Vega Absolute SHVE User Manual

Electronic water meter with lpwan 868 vega radio channel
Table of Contents

Advertisement

The settings package sent to the device may not contain all the settings supported by the device, but
only the part of them that needs to be changed.
Setting IDs and their possible values are shown in Table 10.
Table 10
Setting ID
3
4
8
16
49
55

4.2.3 UNLOCK LED INDICATOR COMMAND

Sending on LoRaWAN port 2. Message structure shown in table 11.
Table 11
Size in bytes
1 byte

4.2.4. TIME CORRECTION

Sending on LoRaWAN port 4. Message structure shown in table 12.
Table 12
Size in bytes
1 byte
8 bytes
Description
Activation type
Confirmed uplinks
Uplinks number of transmissions
Communication period
Data collection period
Timezone in minutes
Packet type, this packet == 2
Packet type, this packet == 255
The value in seconds for which you need to adjust the time.
Can be positive or negative
Length
1 – OTAA
1 byte
2 – ABP
1 – confirmed
1 byte
2 – unconfirmed
1 byte
from 1 to 15
1 – 1 hour
2 – 6 hours
1 byte
3 – 12 hours
4 – 24 hours
1 – 1 hour
2 – 6 hours
1 byte
3 – 12 hours
4 – 24 hours
2 bytes
from -720 to 840
Field description
Field description
Possible values