Optical Port; Internal Clock; Electronic Magnetic Seal; Lorawan - Vega Absolute SHVE User Manual

Electronic water meter with lpwan 868 vega radio channel
Table of Contents

Advertisement

2.3 OPTICAL PORT

There is an optical port (fig. 2) for connection to computer, which also used for testing. The adapter
"Opticalport-USB" connected to the USB-port of computer carries out connection between the optical port
and computer.
"Vega LoRaWAN Configurator" application allows reading and changing the meters parameters. See
detailed application description in a part 3.
The opto-emitter of the optical port is used as a technological optical pulse output for checking the
meter during production. During operation, the meter is verified by the comparison method.

2.4 INTERNAL CLOCK

Time on internal clock may set automatically when the device connects to the "Vega LoRaWAN
Configurator" application and may corrected via LoRaWAN network.
"IoT Vega TimeCorrector" application
network. The device sends time correction request once a week.

2.5 ELECTRONIC MAGNETIC SEAL

The meter has a Hall sensor for fixing of the external magnetic field and it is located under faceplate
of the device (fig.2). That function named as an electronic magnetic seal.
st
From the 1
second of external magnetic field influence, which strong enough, the meter LED
indicator displays warning symbol "b" at the high order digit place (first index) but readings still displaying.
If the external magnetic field influence continues more than 5 minutes, then device locks LED
indicator and send emergency message with lock flag. Herewith, the LED indicator displays warning symbol
"b" but readings not displaying. Only the dispatcher via the LoRaWAN network can unblock a LED indicator
using a special command.
There are device controlling functions, which activated by a magnet getting on external magnetic
field reception area in table 2.
Table 2
Time of external magnetic
field influence
Less than 2 seconds
From 15 to 20 seconds
5 minutes and more

2.6 LORAWAN

2.6.1 CONNECTION TO THE NETWORK

Meter supports two activation methods in the LoRaWAN network:
• ABP (Activation By Personalization) – meter sends data to the LoRaWAN network according to pre-
configured schedule (every 12 hours by
carries out
Event
Optical port activation for 20
seconds
Emergency communication
session, switching from
"Storage" mode
Lock of the LED indicator
default).
an autocorrecting procedure via LoRaWAN
Comment
After 20 seconds, the optical port is
deactivated if it is not in use
While communication session the LED
indicator displays
the high order digit place but readings
still displaying
The LED indicator displays warning
symbol "b" but readings not displaying
warning symbol "p" at
10