3.5 "LORAWAN SETTINGS" TAB

3.5.1 BASIC DESCRIPTION

The "LoRaWAN Settings" tab allows you to configure various parameters of the LoRa network (fig.
14).

3.5.2 FIELDS DESCRIPTION

3.5.2.1 «Region»
"Region" allows you to select RU868, EU868, KZ865 or specify a custom frequency plan (fig. 15).
The meter supports the frequency plans specified in table 3.
Table 3
2
Frequency plan
EU868
RU868
KZ865
Custom
By default, the device supports two frequency plans and the custom, but it is possible to order firmware for
2
other frequency plans: IN865, AS923, AU915, KR920, US915, KZ865
Figure 14 — "LoRaWAN settings" tab
Figure 15 — Region choice
Channel
1
2
3
RX2
1
2
RX2
1
2
3
RX2
Frequency
868.1
868.3
868.5
869.525
868.9
869.1
869.1
865.1
865.3
865.5
867.5
Set with application
Modulation
MultiSF 125 kHz
MultiSF 125 kHz
MultiSF 125 kHz
SF12 125 kHz
MultiSF 125 kHz
MultiSF 125 kHz
SF12 125 kHz
MultiSF 125 kHz
MultiSF 125 kHz
MultiSF 125 kHz
SF12 125 kHz