LG THERMA V HM141MR Installation Manual page 33

Air-to-water heat pump
Table of Contents

Advertisement

CASE 5: Connecting 3
Outdoor
NOTE
• DHW tank
- 3rd Party Boiler
- You can control the boiler automatically and manually by comparing the outside
temperature and the set temperature.
• 3way valve
- It is a valve for DHW use.
- Not installed when installing Buffer Tank
- Type of 3way valve and specification should be complied with
manual.
High Temperature
Low Temperature
Shut-off valve
Magnetic Filter (Mandatory)
M / F
Reverse check valve
rd
Party
3 Way Valve direction
Boiler On :
Boiler Off :
Indoor
R
T
Buffer
Tank
M / F
Room Thermostat(Field supply)
2way valve (Field supply)
By-pass valve(Field supply)
Air vent (Field supply)
GENERAL INFORMATION
Boiler
Floor
Floor
heating loop
heating loop
33
Floor
heating loop
installation
3way valve
(Field supply)
Pump(Field supply)
Aquastat Valve