Binder Serie 423; Connector Pin Description - GeoSIG AC-23 User Manual

Accelerometer
Hide thumbs Also See for AC-23:
Table of Contents

Advertisement

AC-23 Accelerometer User Manual
11.08.2022 / V17
2.2

Binder Serie 423

Cable gland nut has to be determined as per cable external diameter and must be separately ordered. It has
also to provide the cable shield connection to connector case.
2.3

Connector Pin Description

The connector pin assignment and cable colour code can be observed in the table below:
Binder Connector
Serie
Serie
623
423
Pinout
Pinout
1
A
OUTPUT X (+)
2
B
OUTPUT X (-)
3
C
OUTPUT Y (+)
4
D
OUTPUT Y (-)
5
E
OUTPUT Z (+)
6
F
OUTPUT Z (-)
7
G
TEST INPUT
8
H
9
J
+12 VDC power
10
K
11
L
12
M
Table 1. AC-2x Connector Pin Assignment and Cable Colour Code
GeoSIG
Binder Serie 423
Figure 2, Binder Serie 423 connector
SIGNAL
0 V ± 10 V voltage output, 47  output impedance
0 V ± 10 V voltage output inverted, 47  output impedance
0 V ± 10 V voltage output, 47  output impedance
0 V ± 10 V voltage output inverted, 47  output impedance
0 V ± 10 V voltage output, 47  output impedance
0 V ± 10 V voltage output inverted, 47  output impedance
Test input, output will result in a sensor step response
GND
Power input, 10 to 15 VDC range, 90 mA @ 15 VDC
GROUND
Ground, not connected to mechanical ground
AUX
GROUND
Ground, not connected to mechanical ground
P/N #J_CIR.012.010.M
P/N 99 5629 00 12
Comment
Connected to Recorder's GND
Auxiliary input (reserved)
5 / 15
Colour
White
Brown
Green
Yellow
Grey
Pink
Blue
Red
Black
Violet
Grey/Pink
Red/Blue
GS_AC-23_UserManual_V17