Filling With Lubricant - Siemens FLENDER GHZP Assembly And Operating Instructions Manual

Table of Contents

Advertisement

1
Fig. 22: Oil inlet and oil drain on the gear unit
1
Pressurised oil feed
2
Pressureless oil return
A detailed view of the gear unit can be obtained from the drawings in the gear­unit documentation.
Prior to start­up replace the yellow plastic screw plug with the air filter.
For details regarding the auxiliary gear unit, if fitted, see the special operating instructions.
(The auxiliary gear unit is delivered ex works with an oil filling.)
7.1.3

Filling with lubricant

The gear unit is supplied with lubricant by the separate oil­supply system.
The quality of the oil used must meet the requirements of the separately supplied BA 7300
instructions manual, otherwise the guarantee given by Siemens will lapse. We urgently
recommend using one of the oils listed in table "T 7300" (for a link, see the BA 7300 instructions
manual supplied separately), because they have been tested and meet the requirements.
Information on the type, quantity and viscosity of the oil is given on the rating plate on the gear
unit.
The oil quantity shown on the rating plate is to be understood as an approximate quantity. The
marks on the oil­sight glass or angular oil­level indicator are decisive for the amount of oil to be
filled in.
Check the oil level in the gear­unit housing with the angular oil­level indicator or of the oil­sight glass.
The oil must come up to the middle of the oil­sight glass or of the angular oil­level indicator.
Any oil spillage must be removed immediately with an oil­binding agent.
4
3
2
BA 5814 en 09/2014
3
3
Oil­drain plug / oil­drain cock
4
Screw plug / air filter
44 / 61
4
1
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flender ghdp

Table of Contents