4-1-6 Get Image

Original Image Ship
Format
An image is taken whenever the scan operation is done. The last image is always stored in memory. The
original image can be "shipped" by using the %OISHP command.
Down-sampled Image Ship
Format
An image is taken whenever the scan operation is done. The last image is always stored in memory. The
down-sampled image can be "shipped" by using the %DISHP command.

4-1-7 Responses

The embedded scanner responds to a serial command with one of three responses:
<ACK> (0x06)
<ENQ> (0x05)
<NAK> (0x15)
<SYN>M<CR>
0x16 0x4D 0x0D
0x25 0x4F 0x49 0x53 0x48 0x50
<SYN>M<CR>
0x16 0x4D 0x0D
0x25 0x44 0x49 0x53 0x48 0x50
A valid command which has been processed.
An invalid index command.
A command with a valid parameter index and an invalid value.
%OISHP
%DISHP
107
.